Malfunction
Cause
Measure
red LED flashing
• Dirty bar.
• Sparking aganist metallic
machine parts.
• Serious source of EMC
interference in the vicinity
of bar or power supply units
• Clean bar
(see chapter Maintenance).
• Check installation situation.
• Loctate and rectify the source of interfe-
rance, if necessary take measures to
suppress interference
red LED on
• Internal error.
• Acknowledge the malfunction; disconnect
the supply voltage and restart the unit.
• If the malfunction recurs, send the unit for
repair.
No LED on
• Supply voltage not enabled
or not connected.
• Defective internal fuse.
• Defective LED.
• Check supply voltage, connections and
connected cables.
• Acknowledge the malfunction; disconnect
the supply voltage and restart the unit.
• If the malfunction recurs, send the unit for
repair.