Room and DHW programs - settings 

Room  and  DHW  programs  enable  setting  and  maintaining  requested  temperature  at  any  defined  time 
periods with one minute accuracy. Intuitive menu and illuminated display make the programming process 
easy.  All  settings  are  stored  in  non-volatile  memory  and  are  not  deleted  even  in  case  of  a  power  off. 
Electronic  processor  enables  setting  9  independent  programs,  each  can  define  requested  temperature 
within any given time span.  

When two different temperatures from different programs overlap, higher one is prioritized.  

 

 

 

 

MO 

TU 

WE 

TH 

FR 

SA 

SU 

Active days: 

all

 

II 

MO 

 

WE 

 

FR 

 

SU 

Active days: 

4

 

III 

Mo 

 

 

TH 

 

 

SU 

Active days: 

3

 

IV 

MO 

TU 

WE 

TH 

FR 

SA 

SU 

Active day: 

1 (

to choose)

 

MO 

TU 

WE 

TH 

FR 

 

 

Active days: 

working days

 

VI 

 

 

 

 

 

SA 

SU 

Active days: 

weekend

 

VII 

MO 

TU 

WE 

TH 

FR 

SA 

 

Active days: 

6

 

VIII 

 

 

 

 

 

 

 

Active days: 

any

 

IX 

 

 

 

 

 

 

 

Active days:

 any

 

 
1.

 Weekdays, 

2.

 Program start, 

3.

 Program stop, 

4.

 Temp. setting: 20-70°C, 

5.

 Active: yes/no, 

6.

 Program number: from 1 to 9, 

7.

 Function buttons 

 

 

1.8.

 

Settings/ROOM programs

 – press

 on home screen (

C

) and enter SETTINGS (

J

), then choose Room 

programs (

L

) and press

 once more. Using ←→ (

Z

) switch between parameters (weekdays, working time, 

temperature, status), using ↑↓ change parameter value, which is then set by pressing

1.9.

 

Settings/DHW programs 

(for

 AsD-W 

and

 AsDC-W

) – press

 on home screen (

C

) and enter SETTINGS 

(

J

),  then  choose  DHW  programs  (

L

)  and  press

  once  more.  Using  ←→  (

Z

)  switch  between  parameters 

(weekdays,  working  time,  temperature,  status),  using ↑↓  change  parameter  value,  which  is then  set  by 
pressing

Active/Inactive  status

  –  each  program  can  be  temporarily  turned  off.  In  order  to  do  that,  change  status 

within selected program (either Room or DHW one) for: no (

b

). To activate previously turned off program – 

set status for: yes (

a

).  

1.10.

 

Settings/Circulation  pump

  –  press

  on  home  screen  (

C

)  and  enter  SETTINGS  (

J

),  then  choose 

Circulation  pump  and  press

  once  more.  Using  ←→  switch  between  parameters  (weekdays,  working 

time, temperature, status), using ↑↓ change parameter value, which is then set by pressing

Summary of Contents for goldline asbii

Page 1: ...less water heater for central heating systems Electric heating boiler GoldLine series RedLine series AsZN W Pułkownik Uranus Urano AsD W Generał Neptune Nettune AsDC W Marszałek Pluto Plutone AsBII Bateria Sun Sole AsHN Hetman Moon Luna AsBIV Dywizja Galaxy Galassia Please see video prior installation ...

Page 2: ...ELECTRIC HEATING BOILERS for more detailed pictures please see www elterm pl Dimensions and components of AsD W boiler Dimensions and components of AsZN W boiler Dimensions and components of AsBII boiler Dimensions and components of AsDC W boiler Dimensions and components of AsDC W boiler ...

Page 3: ...d for autonomous operation in both open and closed central heating systems safety unit expansion vessel and circulation pumps are included Boiler is build in on top of 100l hot utility water tank equipped with 29kW coil AsBII and AsBIV boilers in closed central heating system in closed type layout the central system needs to be equipped with an expansion vessel which is not supplied with above mod...

Page 4: ...therefore must be done by a qualified electrician only Boilers are designed for alternating current 3 phase power supply 400V 3N 50Hz Models with 4 6 9 12 and 15kW powers are also available without any processing in 1 phase version 230V 1N 50Hz greater powers can also be prepared in 1 phase version upon request Boiler s power supply is connected to terminal strip labeled as L1L2L3N or to switch ig...

Page 5: ...2 5 x 6 0 220 310 21 kW 100 67 33 by 1 6 3 phases 3 x 40 5 x 6 0 260 360 24 kW 100 67 33 by 1 6 3 phases 3 x 40 5 x 10 0 300 400 27 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 220 380 30 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 240 400 33 kW 100 67 33 by 1 6 3 phases 3 x 50 5 x 16 0 260 450 36 kW 100 67 33 by 1 6 3 phases 3 x 63 5 x 16 0 280 480 39 kW 100 67 33 by 1 6 3 phases 3 x 80 5 x 25 0...

Page 6: ...ally for AsD W and there is no possibility do turn heaters on Pre set venting time should be sufficient to carry out the process if however it is not enough whole procedure needs to be repeated by turning boiler off and on again The display switches to the home screen C C H and D H W for AsD W i AsDC W temperature setting enter function from home screen C by pressing using choose either C H or D H...

Page 7: ... will maintain 40 C etc Room temperature setting on boiler I enter function from home screen C by pressing using change preset room temperature in range 5 30 C Detailed settings multiple pressing of causes return to main menu Menu structure J K L 1 Settings 1 1 Power 1 2 Sections 1 3 Date time 1 4 PID P 1 5 Hysteresis CO 1 6 Hysteresis CWU 1 7 Default settings 1 8 Room programs 1 9 DHW programs 1 ...

Page 8: ...e 1 or 2 1 5 Settings CH Hysteresis press on home screen C and enter SETTINGS J then choose CH Hysteresis K and press once more Using T change parameter value range 1 2 3 4 5 6 which is then set by pressing 1 6 Settings DHW Hysteresis press on home screen C and enter SETTINGS J then choose DHW Hysteresis L and press once more Using U change parameter value range 1 2 3 4 5 6 which is then set by pr...

Page 9: ...m start 3 Program stop 4 Temp setting 20 70 C 5 Active yes no 6 Program number from 1 to 9 7 Function buttons 1 8 Settings ROOM programs press on home screen C and enter SETTINGS J then choose Room programs L and press once more Using Z switch between parameters weekdays working time temperature status using change parameter value which is then set by pressing 1 9 Settings DHW programs for AsD W a...

Page 10: ... to check proper pump pumps work Press on home screen C and enter VENTING J Press once more to display D H W C H options d Using change parameter value ON OFF e which is then set by pressing Do not remove boiler external metal casing once device remains turned on In case boiler is activated by mistake with no water inside wait until heaters cool down fill device with water and switch it on again U...

Page 11: ...requirements concerning Ecodesign for energy related products Attachment 13 EU Commission regulation nr 622 2012 With regard to Ecodesign requirements for glandless standalone circulators and glandless circulators integrated in products and that the standards hereinafter referred to have been duly applied and observed The harmonized standards applicable to the product to which this declaration of ...

Page 12: ...e or assembly that is not in compliance with the user manual etc or in the event the guarantee is invalid the costs of repair and travelling are borne by the claimant 6 Failure on the part of the user to follow the serviceperson s recommendations provided in the guarantee repair protocol results in the guarantee being suspended until such recommendations are implemented Do not call servicemen with...

Reviews: