Model 2000 Flow Computer Instruction Manual
APPENDIX 1 ALARM, WARNING & FAULT CODES
Model 2000 issue 21
Page No
70
te1.N hart
A communications failure has occurred between the Model 2000 and temperature sensor 1.
te1.N hsts
Temperature sensor1 is in a sensor generated alarm condition.
te1.N unit
The selected temperature units do not match the units indicated by temperature sensor 1.
te1.N dev
Temperature sensor 1 is outside the deviation limit.
te1.N adev
Temperature sensor 1 is outside the average deviation limit.
prserlN max
The serial check pressure is above the value of pressure.N max.
prserlN min
The serial check pressure is below the value of pressure.N min.
teserlN max
The serial check temp. is above the value of temp.N max.
teserlN max
The serial check temp. is above the value of temp.N min.
qN high
The uncorrected flow rate is above the value of Hi qN. for more than 1 minute.
znN high
Base compressibility outside tolerance znN high.
znN low
Base compressibility outside tolerance znN low.
Calibrate
Unit is in the calibrate mode.
zN calc
Compressibility cannot be calculated.
znN calc
Base Compressibility cannot be calculated.
Modbus err
Modbus Communication port timeout alarm.
For Station Pressure and Temperature only.
S.pr1 max Station Pressure 1 is above the values of S.pr1 max.
S.pr1 min
Station Pressure 1 is below the values of S.pr1 min.
S.pr1 val
There is no value for Station pressure 1.
S.pr1 hart A comms failure has occurred between the Model 2000 and Station pressure sensor 1.
S.pr1 hsts Station Pressure sensor 1 has a sensor generated alarm condition.
S.pr1 unit
The selected Station pressure units do not match the units indicated by Station pressure sensor 1.
S.te1 max Station Temperature sensor 1 is above the values of S.te1 max.
S.te1 min
Station Temperature sensor 1 is below the values of S.te1 min.
S.te1 val
There is no value for Station temperature 1.
S.te1 hart
A comms failure has occurred between the Model 2000 and Station temperature sensor 1.
S.te1 hsts Station Temperature sensor 1 has a sensor generated alarm condition.
S.te1 unit The selected Station temperature units do not match the units indicated by Station temperature
sensor 1.
S.pr2 max Station Pressure 2 is above the values of S.pr2 max.
S.pr2 min
Station Pressure 2 is below the values of S.pr2 min.
S.pr2 val
There is no value for Station pressure 2.
S.pr2 hart A comms failure has occurred between the Model 2000 and Station pressure sensor 2.
S.pr2 hsts Station Pressure sensor 2 has a sensor generated alarm condition.
S.pr2 unit
The selected Station pressure units do not match the units indicated by Station pressure sensor 2.
S.te2 max Station Temperature sensor 2 is above the values of S.te2 max.
S.te2 min
Station Temperature sensor 2 is below the values of S.te2 min.
S.te2 val
There is no value for Station temperature 2.
S.te2 hart
A comms failure has occurred between the Model 2000 and Station temperature sensor 2.
S.te2 hsts Station Temperature sensor 2 has a sensor generated alarm condition.
S.te2 unit The selected Station temperature units do not match the units indicated by Station temperature
sensor 2.
For Turbine meters only.
turbN hf
An hf turbine meter alarm (blade failure) has occurred.
For US meters only.
usN paths
Wrong number of acoustic paths specified.
usN secur.
Meter security alarm bit set.
usN level1
Reduced accuracy alarm.
usN level2
Reduced accuracy alarm.
usN number
Invalid number received alarm.
usN comms
No valid communications from the meter for last 5 seconds.
usN mode
US meter is in non measurement mode (FlowSIC 600 only)
For Orifice plate operation only.
dph1.N max
High range dp sensor 1 is above the values of dp hi 1 N max.
dph1.N min
High range dp sensor 1 is below the values of dp hi 1 N min.
Summary of Contents for 2000
Page 3: ...Model 2000 issue 21 Page No 3 ...
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......