CMS200
Product Manual, Issue 6
www.nexo.com
Page 23
3.4
The menu arrangement
Enter
password
Parameter
List
(PS)
DIF
SP
CF
And
so
on...
Test
Menu
(tSt)
Fault
List
(FLt)
Half
Reset
(Hr)
Full
Reset
(Fr)
Data
Dump
(ddP)
Enter
Full
Reset
Password
Relay
Test
(rEL)
Compressor
(CP)
Light
(LIt)
Fan
(FAn)
Buzzer
(BUZ)
Heater
(Htr)
All
(ALL)
Analogue
Test
(AnA)
Infrared
Test
(Plr)
-
use
to
increase
value
-
use
to
decrease
value
Set
button
-
press
to
select
Defrost
button
-
press
to
return
Up
button
-
press
to
scroll
up
Down
button
-
press
to
scroll
down
Behind each of the main menu headings there is a list for further options:
`
Selecting PS enters the parameter list, and from here parameters and their values can be
viewed, checked and amended as required.
`
Selecting tSt - the test menu allows all inputs and outputs to be tested.
`
Selecting Hr - half re-set - will allow a half reset to be performed which will wipe the learning
matrix, allowing the controller to re-learn outlet opening and closing times.
Note
The full reset is to be performed by Elstat personnel.
The data dump is for Elstat use only for testing and development purposes.