2. Must only be used with an elstat supplied transformer
3. Only used with ems55
advanced
and ems55R
advanced
range
90 to 160 (not Vac)
global default
90 (disabled)
100V line
110-120V line
220-240V line
voltage
LO
voltage
LO
voltage
LO
79
120
95
120
173
130
81
125
98
125
178
135
84
130
100
130
182
140
87
135
103
135
187
145
90
140
106
140
192
150
197
155
Note: Voltage measurement is accurate to ±10%. 203
160
Caution:
l
Low voltage protection is not calibrated and actual performance can be influenced by several factors.
Therefore, total protection cannot be guaranteed.
10.32
learning period (LP)
The table below details the learning period (
L P
) parameter.
display
description
Defines whether the ems controller uses a 1-day or a 7-day learning period.
considerations None
range
00 (1 day) or 01 (7 days)
global default
00 (1 day)
10.33
saving temperature disable (PEr)
The table below details the saving temperature disable (
PEr
) parameter.
display
description
Disables the saving mode temperature so that the ems controller maintains the
ready mode
temperature
at all times.
Disabling the saving mode temperature does not affect the light functionality.
ems55advanced and ems55Radvanced / General Use
78 of 84