The ems controller then scrolls through the statistics pausing for 20 seconds at each statistic before returning to normal
operation.
The 3-digit display can show values from 000 to 999.
For values of 1000 and above, the display shows the value as a rounded decimal number. For example, 1.1 represents 1100,
1.2 represents 1200, and so on.
display
statistic
description
prior to July 2012
description
post July 2012
activity
frequency
Value of the activity frequency
AF
parameter.
Possible values are: 0, 1, 2 or 3.
(0 = low, 2= high and 3 = auto-
matic)
No change
average
temperature
Average temperature
measured by the
appliance sensor
during the last 24 hours.
No change
compressor cycles
Average number of
compressor cycles per day (24
hour period) during the past 7
days (7 x 24 hour
periods).
Note that the average is
a moving average.
Total number of
compressor cycles since
first powered up or last full
reset
compressor runtime
Total number of hours that the
compressor has run since the
ems controller was first
powered up or since the last
full reset.
No change
door
openings
Average number of door open-
ings per day (24 hour period)
during the past 7 days (7 x 24
hour periods).
Note that the average is
moving average.
Total number of door
openings since first powered
up or last full reset
highest
temperature
Highest temperature
measured by the
appliance sensor
during the past 24 hours.
No changes
lowest
temperature
Lowest temperature
measured by the
appliance sensor during the
last 24 hours.
No changes
motion counts
Average number of motion
counts per day (24 hour period)
during the past 7 days (7 x 24
Total number of motion
counts since first powered
up or last full reset
ems55advanced and ems55Radvanced / General Use