ems controllers then copy the pattern learnt from day 1 to the
remaining six days
of the self-learning matrix, as shown in the
following example matrix:
ems controllers with a one day learning period start switching to the
saving mode
on the second day, (second 24 hours), if
there are sufficient saving (0) periods.
ems controller then continue to update the self-learning matrix as follows:
l
For periods set to ready (2), if no activity is detected change to monitor (1). Otherwise, keep the period set to ready (2).
l
For periods set to saving (0), if activity is detected change to monitor (1). Otherwise, keep the period set to monitor (0).
For example, the self-learning matrix shows that the outlet is open for longer on day 2 than day 1.
Therefore, the ems controller has changed the state of the periods that were set to saving (0) to monitor (1) as shown in the
following example matrix.
At the end of week 1, the ems controller has updated the self-learning matrix for the outlet activity pattern as shown below.
Note that differences for activity patterns learnt on day 2 take two weeks to be implemented. Therefore, 1 day learning peri-
ods are recommended only for outlets with regular patterns every day of the week.
ems55advanced and ems55Radvanced / General Use