9.
Press the up button to start, and test, the analogue inputs described in the following table:
button
display
test
check
appliance
sensor
temperature
displayed temperature is correct
door switch
door is open (
dO
) or closed
(
C L O
)
or
condenser
sensor
temperature
displayed temperature is correct
evaporator
sensor
temperature
10. Press the defrost and set buttons simultaneously to test the motion sensor.
The display changes to
PI r
.
11. Press the defrost button and then place your hand about 300mm in front of the motion sensor.
Move your hand from left to right and ensure the following:
l
The display count increments for each detected movement.
l
The motion LED flashes for each detected movement.
12. Press the defrost and set buttons simultaneously to end the test routine.
7.7
how to perform a half reset (Hr)
Perform a half reset to clear the self-learning matrix if the ems controller has been unable to detect activity correctly, for
example, the view of the motion sensor was blocked, or if the cooler has been moved to a new location.
Perform a half reset as follows:
1.
Press and hold the set button until
PAS
is displayed.
2. Enter the button sequence of the
menu entry
password.
3. Ensure that
PS
is displayed.
4.
Press down to scroll down to the
Hr
menu.