6
Manual mode activated. The connected drive mechanism was
operated manually (with arrow keys) or
key was pressed. Thus,
the automatic functions are deactivated, there is no control in terms
of lightness or temperature. The safety functions rain alarm and wind
alarm are still activated. The control is in manual mode until you
change to automatic mode with
key.
Rain alarm. Exterior awnings are retracted, manual operation is
blocked. The rain protection function may be turned on and off in the
automatic settings (e.g. for internal awnings or blinds).
Wind alarm. Exterior awnings or blinds are retracted, manual
operation is blocked. The wind protection function may be set up or
turned off in the automatic settings (e.g. for internal awnings).
Display of lightness and wind speed
Press the
key during temperature display once for a short moment, and
current lightness (in kilolux, kLux) and wind speed (in meters per second, m/sec)
are displayed. The values are updated every 4 seconds.
Note: During the first approx. 90 seconds after the return of voltage at the
weather station, the wind value is not displayed correctly (e.g. after a power fail
or in case of a first start). Therefore, manual operation is blocked in this period of
time in case of activated wind alarm.
If you press the
key again for a short moment, you get back to the
temperature display (or to the central command display, see next chapter). After
approx. 60 seconds, the display switches automatically to the temperature
display.