14
E. Outdoor temperature block
After the setting of the indoor temperature block, now select the outdoor
temperature below which shading shall be prevented.
The outdoor temperature block is important for exterior sun protection systems.
In case of frost, the awning or blind may freeze in the slide rails. If the shading is
then moved, it may be damaged. Please note that the slide rails or other
mechanical components may still be frozen although the outdoor temperature
has considerably high values. Please enquire the blocking temperature for your
shading at your winter garden manufacturer.
The delay (hysteresis) of the outdoor temperature block is 2°C. That means, the
shading is released only after the outdoor temperature has extended the set value
more than 2°C.
If your shading also operates at low temperatures or if it is installed indoor,
please deactivate the outdoor temperature block (display
).
Outdoor as well as indoor temperature blocks only apply for
the automatic mode. Manual operation is further possible.
Therefore, please observe possible icings if you open and
and close manually.
The presetting for the outdoor temperature block is 5°C.
Adjust the value with (higher) and (lower) or select
(off) in order to
switch off the outdoor temperature block. You reach the setting
by pressing
once more when the display shows “-20°C”.
Then press
in order to access the setting of the next parameter.