Transmission protocol

Door operator control module KNX A3-B2

 • Status: 17.12.2019 • Technical changes and errors reserved.

4.

Transmission protocol

Units:

Time in seconds
Dimming in percent
Temperature in 0.1°C
Brightness in kLux

4.1. List of all communications objects

EIS types:

1

1 / 0 switch

5

Floating decimal value

6

8-bit value

Abbreviation flags:

R

Reading

W Writing
C

Communication

T

Transmission

No.

Text

Function

DPT

Length 
(byte)

Flags

0

Output 1 - Impulse
[In Defined Open/Close/Stop 
mode: 
Output 1+2 - Impulse 
(1=open | 0=close)]

Input

1.001

1

RC

1

Output 2 - Impulse

Input

1.001

1

RC

2

Output 3 - Impulse
[In Defined Open/Close/Stop 
mode:
Output 3 - Impulse (1 or 0)]

Input

1.001

1

RC

11

Input 1 Extended

Input/Output

1.008

1

RWCT

12

Input 1 Short

Output

1.010

1

R CT

13

Input 1 Switching

Input/Output

1.001

1

RWCT

14

Input 1 Relative dimming

Input/Output

3.007

1

RWCT

15

Input 1 Encoder 8 bit

Output

5.*

1

R CT

16

Input 1 Encoder Temperature

Output

9.001

2

R CT

17

Input 1 Encoder Brightness

Output

9.004

2

R CT

18

Input 1 Scene

Output

18.001

1

R CT

19

Input 2 Extended 

Input/Output

1.008

1

RWCT

20

Input 2 Short

Output

1.010

1

R CT

21

Input 2 Switching

Input/Output

1.001

1

RWCT

Summary of Contents for 70391

Page 1: ...EN Installation and Adjustment KNX A3 B2 Door Operator Control Module Item number 70391...

Page 2: ......

Page 3: ...cription 3 1 0 1 Deliverables 3 1 1 Technical data 3 2 Installation and start up 4 2 1 Installation notes 4 2 2 Installation 4 2 2 1 Installation location 4 2 2 2 Connection layout of the circuit boar...

Page 4: ...eshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous s...

Page 5: ...1 0 1 Deliverables Control module in the installation casing Connection line for outputs Connection line for inputs 1 1 Technical data Housing Plastic Colour White Assembly Installation Protection ca...

Page 6: ...st unintentional use if it can be assumed that risk free operation is no longer guaranteed The device is only to be used for its intended purpose Any improper modification or failure to follow the ope...

Page 7: ...the bus cable red black clamp Use the 8 wire connection line to connect the outputs and the 4 wire line to connect the binary inputs The lines may be extended to up to 5 m Outputs Binary inputs Progr...

Page 8: ...e bus voltage has been applied the device will enter an initialisation phase last ing a few seconds During this phase no information can be received or sent via the bus 3 Addressing of the device at t...

Page 9: ...mode Output 1 2 Impulse 1 open 0 close Input 1 001 1 RC 1 Output 2 Impulse Input 1 001 1 RC 2 Output 3 Impulse In Defined Open Close Stop mode Output 3 Impulse 1 or 0 Input 1 001 1 RC 11 Input 1 Exte...

Page 10: ...1 2 Impulse If the object value is 1 then output 1 receives an impulse closes for 1s If the object value is 0 then output 2 receives an impulse closes for 1 s Output 3 is asigned to the object Output...

Page 11: ...closes at value 0 it opens Output 3 react to the object is assigned to the object Output 3 Impulse and gets an impulse closes for 1 second at object value 1 In addition monitoring can be set After th...

Page 12: ...control of one or two doors When receiving Output 1 Impulse when object value 1 Output 1 closed When receiving Output 1 Impulse when object value 0 Output 1 open When receiving Output 2 Impulse when...

Page 13: ...me interval switching dimming and if requested the repeat interval for a long button press Send value no change for change to 1 for change to 0 for change and cyclical for change to 1 and cyclical for...

Page 14: ...and shall be used as a brightness encoder e g threshold value of a sun sensor select brightness encoder and specify which value will be sent Input for scene control If scenes are called and saved with...

Page 15: ...tuation shorter than Time 1 The drive is positioned step wise and stopped Holding it slightly longer longer than Time 1 but shorter than Time 1 2 Drive running Drive stops when the button is released...

Page 16: ...time 2 expires Stop Release after time 1 2 expired Move into end position Control mode Comfort mode Behavior during button operation Button is pushed and released before time 1 expired stop step held...

Page 17: ......

Page 18: ...bH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49...

Reviews: