Auto Close is a feature that automatically closes the gate after a preset time has counted down to zero. The 
control card has a normal Auto Close and several special Auto Close features each one having its own 
countdown timers.

Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto 
Close options are used.

If the Stop input is activated Auto Close is disabled for that cycle only. 

Auto Close timer will not count down if the Push Button, Open or Photoelectric Beam input is held active.

Menu No.

Auto Close Features

Factory 

Default

Adjustable

1.1

Normal Auto Close

Off

1 - 600 seconds

1.2

Auto Close with Photoelectric Trigger

Off

1 - 60 seconds

1.3

Auto Close after an Open Obstruction 

Off

1 - 60 seconds

1.4

Auto Close after Power Restored

Off

1 - 60 seconds

1.5

Normal Auto Close on Sequential Obstructions

2

Min = Off, 

Max = 5

1.6

Auto Close Only when Fully Opened

Off

Off/On

1.7

Exit

Menu 1 – Auto Close

1.1 Normal Auto Close

The gate will close after this timer has counted down to zero.

1.2 Auto Close with Photoelectric Trigger

This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger 
even if the gate is not fully open. If there is no Photoelectric Beam trigger the gate will not Auto Close.

1.3 Auto Close after an Open Obstruction 

If the gate opens and hits an obstruction normally the gate will stop and remain in this position. If this 
feature is enabled an obstruction will start the timer count down and at zero will close the gate. 

12

Gate & Door Controller

 with Eclipse

®

 Operating System (EOS)

Summary of Contents for Eclipse MCS

Page 1: ...www elsema com MCS Motor Controller Single Setup and Technical Information Includes latest Intelligent Technology Motor Controller Single Gate with Eclipse Operating System EOS 4th Edition Eclipse MCS...

Page 2: ...goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods Any figures or estimates given for performance of goods are based upon the company s experience a...

Page 3: ...Input Functions 14 Menu 4 Photoelectric Beam 15 Menu 5 Relay Output Functions 16 Menu 6 Relay Output Modes Relay Output Modes 19 19 Menu 7 Special Features 22 Menu 8 Motor Obstruction 23 Menu 9 Motor...

Page 4: ...next generation but the Next Transformation in the gate and door industry creating an Eclipse over previously developed motor controllers This new intelligent motor controller is the best match for y...

Page 5: ...S12E plus 12 Volt 2 3Ah backup battery MCS24E7 Same as MCS24E plus 24 Volt 7 0Ah backup battery MCS12E7 Same as MCS12E plus 12 Volt 7 0Ah backup battery Solar Gates Solar24SP Solar kit for double or s...

Page 6: ...trobe Warning Light 5 2 Relay Output 2 9 1 Open Speed 9 2 Close Speed 12 1 Enter Password 12 2 Delete Password 14 1 Battery Type 14 2 Supply Voltage 3 1 PE Polarity 3 2 Limit Sw Polarity 8 1 Open Obst...

Page 7: ...Open 9 6 Stop Rev Delay Time 9 7 EXIT 12 3 EXIT 14 3 Reset Factory Default 14 4 Test Inputs 3 3 Stop Input Polarity 8 3 Slow Speed Obstruct 10 3 Electronic Braking 6 3 Strobe Warning Light 14 5 Trave...

Page 8: ...on Open Close Stop Common PED Access Photo Beam 12 VDC 12 VDC Output 1 C Output 1 NO AC Supply 24 12 Volts AC Model MCS Designed by ELSEMA IN AUSTRALIA Normally Closed User can change ELSEMA Normally...

Page 9: ...actory default setting for each input Normally Closed User can change Fuse Relay Open Close Stop Master Control Open Limit Common Motor 1 Close Limit Motor 1 Push Button Open Close Stop Common PED Acc...

Page 10: ...er can change M Motor 1 Fuse Close Master Control AC Supply 24 12 Volts AC Model MCS Designed by ELSEMA IN AUSTRALIA AC Supply AC Supply Motor Motor M Close Limit Open Limit Diode Diode 6 Amps 50V or...

Page 11: ...l automatically prompt you to do the i Learning 3 Look at the LCD and follow the instructions displayed 4 Buzzer will indicate learning was successful If there was no buzzer check all electrical wirin...

Page 12: ...Auto Close after an Open Obstruction Off 1 60 seconds 1 4 Auto Close after Power Restored Off 1 60 seconds 1 5 Normal Auto Close on Sequential Obstructions 2 Min Off Max 5 1 6 Auto Close Only when Fu...

Page 13: ...lly open Menu 2 Pedestrian Access There are several types of Pedestrian Access modes Pedestrian Access opens the gate for a short time to allow someone to walk through the gate but does not allow acce...

Page 14: ...This setting sets the amount of times the gate will try to Auto Close After trying for the set limit the gate will remain open When turned OFF the gate will always try to Auto Close 2 5 Pedestrian Acc...

Page 15: ...stops gate on close cycle PE Beam stops gate on open close cycle PE Beam stops and closes gate on open cycle 4 2 Exit The factory default for the PE beam input is normally closed but this can be chang...

Page 16: ...contacts Factory default is lock brake release function Output 2 is an open collector output Factory default is courtesy light function Menu No Output Function Factory Default Adjustable 5 1 Output 1...

Page 17: ...e common The normally open contact powers the device See diagram below Courtesy Light The factory default for the courtesy light is on output 2 Output 2 is an open collector output This output is used...

Page 18: ...ice is due Strobe Warning Light when Opening or Closing The relay output is activated whenever the gate is operating The factory default is Off Either output 1 or output 2 can be changed to strobe War...

Page 19: ...ction Factory default is 2 seconds Setting it to Hold means the output is activated for the total travel time in the open direction 6 1 2 Close Lock Brake Activation This sets the time the output is a...

Page 20: ...be configured in different ways Menu No Strobe Warning Light Mode Factory Default Adjustable 6 3 1 Pre Open Strobe Warning Light Activation Off 1 30 seconds 6 3 2 Pre Close Strobe Warning Light Activa...

Page 21: ...mber of cycles is completed Connecting Elsema s GSM receiver to the output allows owners to get a phone call SMS message when the service is due When Service Call Due message shows up on the LCD a ser...

Page 22: ...ose the gate In public access areas user should only be able to open the gate and not worry about closing it Usually the Auto Close is used to close the gate This mode disables closing for the remote...

Page 23: ...en and close direction The minimum margin will allow least pressure applied to trip the gate if it hits an object The maximum margin will allow for a large amount of pressure applied to trip the gate...

Page 24: ...d i Learn has to be done again 9 1 9 2 Open and Close Speed This sets the speed at which the gate will travel If the gate is travelling too fast reduce this value 9 3 Slow Speed This sets the speed at...

Page 25: ...in the fully open or fully closed position this feature applies a reverse voltage for a very short time It will prevent the motor from jamming up the gate so it is easy to disengage the motors for man...

Page 26: ...use Protect Obstruction 13 2 Displays Gate Operations and Current Levels This displays the number of open cycles close cycles pedestrian cycles open obstructions close obstructions and motor current l...

Page 27: ...test all the external devices connected to the controllers inputs UPPERCASE means input is activated and lowercase means input is activated 14 5 Travel Timer for Slip Clutch Motors This allows you to...

Page 28: ...will disable the automatic voltage sensing which could causes problems in solar applications Pre made Inductive Loops Loop Detectors Elsema has a range of Saw Cut and Direct Burial loops They are pre...

Page 29: ...s to act as a warning when the gate or doors is in operation PentaFOB Programmer PentaFOB Programmer Add edit and delete PentaFOB remotes from the receiver s memory The receiver can also be password p...

Page 30: ...ch activates the receiver 3 Press the button on the new remote which needs to be programmed for 2 seconds 4 Press the program button again of the remote in step 1 The receiver exits learning mode 5 Pr...

Page 31: ...31 www elsema com...

Page 32: ...ington Place Smithfield NSW 2164 Australia P 02 9609 4668 W www elsema com Sliding gate motor kits Sliding gate motor kits Swinging gate motor kits Swinging gate motor kits Motor control cards Kits Ke...

Reviews: