Lock / Brake Output
The factory default for output 1 is lock/ brake release. Output 1 is a voltage-free relay contact with
common and normally open contacts. Having it voltage-free allows you to connect either 12VDC/AC,
24VDC/AC or 240VAC to the common. The normally open contact powers the device. See diagram below:
Courtesy Light
The factory default for the courtesy light is on output 2. Output 2 is an open collector output. This output
is used to switch an external relay such as Elsema’s REL12-1 which can be purchased separately. See
diagram on the next page.
Relay
Open Close Stop
12VDC/AC
24VDC/AC or
240VAC Supply
+ if DC
Output 1 C
Output 1 NO
- if DC
Lock/Brake
17