Technical Manual TAR x810-2 Cold Storage Controllers  

Page 7

Dimensions / Wiring TAR 3810-2

13

32

105 (4.13)

2

1

3 4 5

9

7

6

8

10

12

11

25

23

22

20 21

24

TAR

27

26

29

28

31

30

46 (1

.81)

63 (2

.48)

91 (3

.58)

ELREHA

16

14 15

17 18 19

P

34

33

35 36 37 38

RS

485

NDO

cooling

(K1)

1

PE

N

3

2

4

6

5

8

7

N

TAR 3810-2

mains

N

L

L

L

DI1

L

AC

24

23

DO

0-

10V

 O

UT

DC

26

25

27

lim

itat

io

sensor

 (

F2)

cont

rol 

sensor

 (

F1)

16

13

11

9 10

12

15

14

defrost

(K2)

fan

(K3)

17 18 19

alarm

(K4)

35

28 29 30 31 32 33 34

36 37 38

Panel housing dep. on DIN 43700/IEC 61554

Cut-out:   

92 x 45 mm (b x h)

Tolerances max: 

+0,8 (b), +0,6 (h)

2/

4/

ELREHA

1/

3/

P

TAR 

45

 (1

.77

)

49

 (1

.93

)

1

30

12 1

3 14

15

2

3

24 2

5

4

5

6

7

8

9 10

11

26 2

7 28

29 3

0

1

16 1

7 18

19 2

0 21

22 2

3

119 (4.69)

DI 1

92 (3.62)

22

7

29
30
31

25
26

23

24

13

15

14

12

10
11

8

9

K 4

K 3

K 2

DO
GND

NDO

3
4
5
6

2

L
N

PE

1

21

K 1

20

17

18
19

F2

16

F1

97 (3.81)

  Made in Germany

ELREHA

8

35

(1

.3

8)

59 (2.32)

26 (1.02)

39 (1.54)

For all described products there is a declaration of conformity which describes that, when operated in accordance with the technical manual, the 

criteria have been met that are outlined in the guidelines of the council for alignment of statutory orders of the member states on EMC-Directive  

(2004/108/EC) and the Low Voltage Directive (LVD 2006/95/EC). This declarations are valid for those products covered by the technical manual 

which itself is part of the declaration. To meet the requirements, the currently valid versions of the relevant standards have been used.
This statement is made from the manufacturer / importer 

by: 

ELREHA Elektronische Regelungen GmbH 

Werner Roemer, 

Technical Director 

D-68766 Hockenheim 

 

 

 

 

 

 

www.elreha.de   

Hockenheim

.............

11.06.2008

.......................................................

(

name / adress

city 

date

 

 

sign

EG-Conformity

Dimensions / Wiring TAR 5810-2

Summary of Contents for TAR 1810-2

Page 1: ...ingle differences Changed terminal assignment Be careful while replacing older types Error messages now shown as codes and displayed as listing at P52 Unlock Acess code entry now possible at each para...

Page 2: ......

Page 3: ...g function is locked automatically Manual Defrost While the actual value is visible Press key for more than 2 seconds Defrost ON Press key for more than 2 seconds Defrost OFF Start up behavior Directl...

Page 4: ...frigeration P11 88 Refrigeration Compressor Idle Time 0 59 minutes 2 minutes P12 88 Fan stop go temperature 100 C 100 C Hyst 3K fixed 50 C P13 88 Fan mode 1 2 3 4 see text 1 P14 88 Fan delay after def...

Page 5: ...four times available P24 P27 B by digital input DI1 see chapter digital input In this case P35 will take effect as a defrost OFF time C manually P49 The defrost device is always driven from the n o co...

Page 6: ...als 11 12 Never connect mains voltage to these terminals danger of destruction This external contact must be suitable for 5VDC 1mA Because all units are connected parallel on the data bus every unit h...

Page 7: ...0 11 8 9 K 4 K 3 K 2 DO GND NDO 3 4 5 6 2 L N PE 1 21 K 1 20 17 18 19 F2 16 F1 97 3 81 Made in Germany ELREHA 8 35 1 38 59 2 32 26 1 02 39 1 54 For all described products there is a declaration of con...

Page 8: ...age under unfavourable conditions The device is strongly draggled or wet After inadequate shipping conditions Never use this product in equipment or systems that are intended to be used under such cir...

Reviews: