ERT-A2 ALERT2 Configuration Manual
Revision 1.0
30
setup and the value to settle before ERTA2
sample. Consult with transducer instruction
manual for this value. 10 seconds is a good
default if unknown. Best to keep this value as
short as possible for best energy usage.
River Sensitivity (mm): 10
Value in engineering units that the input will
need to change before a event is triggered.
Configuring Battery Voltage ID 8
Automatic configuration of internal or external
battery voltage to be configured as a unsigned
1 byte value with 0.1V increments, sensor ID 8.
Configuring RSSI ID 10
Automatic configuration of cellular RSSI or
satellite signal qualtiy to be configured as a
signed 1 byte value, sensor ID 10.
Configuration Change Complete
Sensor input configuration is complete, but not
saved. To save return to main menu and select
Display and Save configuration option.
Once the ALERT Sensor quick setup is completed you will be returned to the Unit Config Menu. Note
that you will see a message in menu header “Config NOT saved”
to warn that changes have been
made and will not be activated until saved through main menu option
, “Show/Save Configuration”.
Move back to main menu but hitting Enter key and then select the Show/Save Configuration.
Review the configuration and when prompted to save select Y to save and activate the
configuration. Selecting N will discard the configuration.
Show/Save Configuration example:
Current Configuration: Station Address: 4300
External Inputs
DI1
DI2
DI3
DI4
AI1
AI2
Mode
Incr
Quad
Pulse
On/Off
4-20mA
4-20mA
Raw
4294967295 0
893005
Off
16.15 mA 0 mA
ID
-
-
0
-
7
-
Format
#-#
#-#
#-#
#-#
Scale
1
1
1
1
5000
16000
Offset
0
0
0
0
0
4000
Sens
1
1
10
2
10
1000
Value
#255#
#0#
893006mm #0#
3798mm
#0#
Internal
Status
Battery
Supply
RSSI
Int Tmp
ID
8
9
10
12
Format
U-1
U-1
S-1
S-2
Value
13.3 V
24.3 V
-75dBm 23degC
Analog Sample Time:
5min
Analog Warmup Time:
4sec
Update Time:
15min
Paralysis Time:
600sec
ALERT Protocol Mode:
ALERT2 ASCII Protocol
Serial Port Mode:
4G Modem Reporting
Baud
Bits
Parity
Stop
IP Port
Destination Host
9600
8
n
1
31025
10.255.40.155