To decode or specify product ordering code use the table below:
Part Number
EL-ERT-A2
-C
G
R
-X
A
Base Config
Enclosure
ERRTS Std Mil Spec
-M
Cable Gland
-C
1/2" NPT
-N
ALERT1 Upgrade Kit -U
GPS
Fitted
G
Not Fitted
X
Battery
Internal rechargeable
R
Internal non rechargeable
P
External
E
Primary
Comms
Licence Free/Licenced
150MHz 5W
-1
300MHz 10W
-3
400MHz 10W
-4
500MHz 10W
-5
150MHz 25W
-H
Not Fitted
-X
Secondary
Comms
Cellular 4G LTE Gtwy
APAC
A
Americas
U
Europe
E
Satellite Gateway
Sat
S
Not fitted
Blank
X
Order model guide Notes:
•
Not all possible build options above are available for order. Please check with your ELPRO
supplier.
•
Example: Cable gland, internal rechargeable battery, secondary AU cell radio, EL-ERT-CXR-
XA
•
All models with primary VHF/UHF radio -1, -3, -4, -5 and -H require GPS option for ALERT2
TDMA operation.
•
Cellular/Satellite options do not require GPS option, time clock sync performed through
cell/sat network
•
150MHz 25W Power Amplifier (PA) option will not allow secondary communications Cellular
or Satellite gateway fitment in single enclosure. If Cellular or Satellite gateway is required
with 25W PA option, then the gateway unit is ordered separately as a standalone IP
enclosure with RS232 link to ERT-A2 unit.