background image

Document: EP6002Eb

3 - EN

Symbols and Description Codes Used

Information

IMPORTANT INFORMATION AND WARNINGS

DELETE

Windows functions, for example Delete

<xxxxxxxxx>

Syntax for placeholders.
Placeholders are written in < > brackets.

Reference to related chapter or document.

Presentation only refers to part of the
user interface.

Ethernet cable

WLAN / WiFi, radio connection between: Base, WLAN modules and 
customer network.

Radio connection between radio modules

In the interests of our customers, we reserve the right to make any changes 
resulting from technical advances. For this reason, diagrams, descriptions, and 
the scope of delivery are subject to change without notice. This manual is valid as 
from Version 2017.

CHANGES OR MODIFICATIONS MADE TO THIS EQUIPMENT MAY INVALIDATE THE 
ETSI /

 

FCC AUTHORIZATION TO OPERATE THIS EQUIPMENT.

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC: OPERATION IS SUBJECT TO 
THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE ANY HARMFUL RADIO INTERFERENCE, AND 
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING 
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
THIS CLASS B DIGITAL DEVICE COMPLIES WITH THE CANADIAN
ICES-0003.

- This device complies with the fundamental requirements the Radio Equipment Directive 

(RED) 2014/53 / EU.

- This device complies with EU radiation exposure limits for an uncontrolled environment.
- This device should be installed and operated at a minimum distance of 20 cm between 

the radiator and your body.

- The device contains the FCC ID: TX2-RTL8821AE and
- IC: 6317A-RTL8821AE

- This product must be disposed of in accordance with WEEE (Waste Electrical and 

Electronic Equipment, 2002/96/EC).

Summary of Contents for ECOLOG-PRO Base

Page 1: ...ECOLOG PRO Base Operation Manual...

Page 2: ...ion 8 3 ECOLOG PRO Base Maintenance 12 3 1 Region 12 3 2 Network 13 3 3 Database 14 3 4 Update 15 3 5 System 15 3 6 WebAccess 16 3 7 Example of a Configuration Report 17 4 Operating Modes 18 4 1 Conne...

Page 3: ...ICATIONS MADE TO THIS EQUIPMENT MAY INVALIDATE THE ETSI FCC AUTHORIZATION TO OPERATE THIS EQUIPMENT THIS DEVICE COMPLIES WITH PART 15 OF THE FCC OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1...

Page 4: ...ference guide to initial startup of up the ECOLOG PRO Base However it contains no basic principles on setting up or operating a network ECOLOG PRO Base 801417 Application Maximum number of measuring d...

Page 5: ...ingress of water humidity may cause damage to the device IR radiation heat and superheated steam may damage the surface coating of the casing No guarantee can be given if functions exceed the specifie...

Page 6: ...used for configuration updates and service work by ELPRO Note on initial startup The sections 2 1 ECOLOG PRO Base to 2 3 WLAN Connection are also described in the document EP6401A which is supplied al...

Page 7: ...or Remove the USB stick Plug the USB stick in the PC File Open the file NetworkConfig txt Use the IP address below the line Desc Intel R Ethernet Connection 2 I219 V to log in to the ECOLOG PRO Base O...

Page 8: ...ase Open the web browser and run initialization 2 4 Initialization Path http 192 168 253 106 Maintenance At initial startup the ECOLOG PRO Base is initialized by the configuration wizard on the ECOLOG...

Page 9: ...the configuration wizard is displayed in the following procedure Next Back Skip forward or backward in the configuration wizard Administration IMPORTANT If you forget this password ELPRO can reset it...

Page 10: ...inish Select the national settings for date and time End your input for the current time with DONE Check your settings and end the initializa tion IMPORTANT YOU CANNOTRESTART THE WIZARD AFTER YOU END...

Page 11: ...ITIAL STARTUP 11 EN Restart Log in to the ECOLOG PRO Base using the username and password set on delivery The application ECOLOG PRO Base Maintenance in the dashboard view starts after login 3 ECOLOG...

Page 12: ...Maintenance Login ECOLOG PRO Base Mainte nance 2 From the elproMONITOR application Menu BASE Login ECOLOG PRO Base Maintenance elproMONITOR REPORT Generates a report containing the present settings o...

Page 13: ...work drive used as backup drive for example Activate the selection box and enter the data required or Select the option of either period or comma for display DD MM YYYY DD MM YYYY MM DD YYYY YYYY MM D...

Page 14: ...INGS Database Daily backup active Starts automatically a daily backup of the databases to the selected drive Select the backup destination BACKUP NOW The database backup is started manually to the dri...

Page 15: ...Base 3 5 System SETTINGS System Language for audit trail The language selected is used for events audit trail entries xxxxxxx Settings for comments and acknowledging warnings and alarms System Time M...

Page 16: ...the alarm protocol Alarm Group Logger Directory These three boxes define the names of the directories in each case The 3 directories are created as subdirectories on the network drive specified The al...

Page 17: ...Document EP6002Eb ECOLOG PRO BASE MAINTENANCE 17 EN 3 7 Example of a Configuration Report Configuration report pages 1 and 2 The configuration report is only available in English at present...

Page 18: ...les can be connected by LAN ECOLOG PRO LBR ECOLOG NET LR8 ECOLOG NET LP4 ECOLOG NET LA8 Application example Using the system in an autonomous network All components are connected to a switch No connec...

Page 19: ...the system in the customer network All components are connected over the customer LAN Local Area Network or WAN Wide Area Network A connection to the web is possible required for remote support from E...

Page 20: ...PRO Base The UPS bridges for 10 seconds and ensures a controlled switch off of the ECOLOG PRO Base without data loss Power supply unit contained in the scope of supply of the ECOLOG PRO Base Input vo...

Page 21: ...customer data required Customer name ECOLOG PRO Base serial number email address Reset data is generated by ELPRO Data is sent to the customer by email Customer saves the data on a USB stick Customer...

Page 22: ...pe of Supply 1 ECOLOG PRO Base Part Number 801417 1 control cabinet fitting materials support rail fitted to the rear 2 antennas 2 4 GHz and 5 GHz 4 rubber feet self adhesive 1 spare filter 1 power su...

Page 23: ...ISION HISTORY 23 EN 8 Revision History Author Date Version Description JOGAU June 29 2018EP6002Ea Document author JOGAU July 3 2018 EP6002Eb No special characters are permitted for the admin password...

Page 24: ...Manual ECOLOG PRO Base EP6002Eb 03 Jul 2018 ELPRO BUCHS AG Langaeulistrasse 45 9470 Buchs SWITZERLAND E Mail swiss elpro com...

Reviews: