Chapter 7
Warranty
MAN_105G_1.16
Page 134
The online diagnostics menu is also referred to as the “Debug” menu. The Debug Menu
allows the Radio Interface (I/O Registers) to be viewed and modified to confirm the operation
of the radio network. These options may be used to check operation of outputs at remote
sites, and to check the values of inputs reported from remote sites. When the protocol driver
does
not
use the shared RS232/485 port (Ethernet, Profibus, DeviceNet, and Modbus Plus)
data is also exchanged with the fieldbus and the I/O Registers according to the configured
fieldbus mappings.
Option a) Read Image Array
Displays the I/O registers of the Radio Interface - the register values for a block of 50
registers are updated every 1 second. For example, to display the I/O Database value at
locations 0 to 49.
Select a), then enter Location: 0
0 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
10 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
20 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
30 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
40 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
Note that I/O Image locations are specified in decimal, whereas register values are displayed
and specified in hexadecimal. If you want the 105G to stop the host device writing values to
the I/O database at the same time, then select option i) Disable Fieldbus Write Area.