Answer from slave to master:
Transmission of the process reflection
The slave sends the following parameter-values:
Byte 1 + 2:
status setpoint transmission:
the last instruction was OK.
Byte 3 + 4:
Zone 1
Act. process temp. value:55,0°C
550de c.=0x0226hex., 16 bit integer-value
Byte 5:
Zone 1
Controller status:
controller = on
Byte 6:
Zone 1
Alarm status:
alarm = no alarm
Byte 7 + 8:
Zone 2
Act. process temp. value:56,0°C
560de c.=0x0230hex, 16 bit integer-value
Byte 9:
Zone 2
Controller status:
controller = on
Byte 10:
Zone 2
Alarm status:
alarm = Alarm 2 active
.
.
.
.
64: Zone 16
Act. process temp. value
Byte 65:
Zone 16
Controller status
Byte 66:
Zone 16
Alarm status
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Status
Setpoint
High Byte
0x00
Status
Setpoint
Low Byte
0x00
Zone 1
Process
Value
High Byte
0x02
Zone 1
Process
Value
Low Byte
0x26
Zone 1
Controller
Status
0x00
Zone 1
Alarm
Status
0x00
Byte 7
Byte 8
Byte 9
Byte 10
Zone 2
Process
Value
High Byte
0x02
Zone 2
Process
Value
Low Byte
0x3A
Zone 2
Controller
Status
0x00
Zone 2
Alarm
Status
0x02
. . .
Byte 63
Byte 64
Byte 65
Byte 66
. . .
Zone 16
Process
Value
High Byte
0x..
Zone 16
Process
Value
Low Byte
0x..
Zone 16
Controller
Status
0x..
Zone 16
Alarm
Status
0x..
If there are instruments with controller zones lower than 16 (e.g. 8 or 12 zones) the number of the
transmitted data bytes is lower too.