- If the safety input remains free:
Ensure that the contact makers of this safety input are bridged.
10 Electrical connection
- Electrical connection is only permitted in a voltage-free state.
- Make sure that the details described in the technical specifications are al-
ways complied with.
- Measures to improve the equipment’s immunity to interference from line-
conducted and radiated high frequency interference are to be taken
(DIN EN 60204-1:2007-06, para 4.4.2).
When connecting the sensor, the sensor power supply voltage (+) and (-)
terminals identified in the technical specifications are to be used.
Terminal connections
11 Commissioning
In random order:
- Damp safety sensors.
- Apply operating voltage.
- Then actuate the start button if necessary.
The LEDs of the inputs and outputs used and the "Ready" LED light up.
The safety control unit is ready. The safety control unit switches through the
safety output.
Art.-Nr./Art. No./Réf./N° art/N° art.: 9010008B01M
V
ersion: 1.3
Accessories
Spring terminals are supplied as standard (order number
878598).
Optional screw terminals (order number 878719) and dou-
ble terminals (order number 878717) are available from
elobau.
A corresponding coding tab set is available from elobau un-
der order number 350SAE001.
Components
Terminals Explanation
Safety input 1
5-8
Depending on configuration, the inputs at
terminals 5, 13, 21, 29 (+) or (-) are read-
only.
Connection options:
- Sensors with 2-NO system
- Sensors with NO/NC System
- Emergency stop push button
- 2-hand control
- Light grid (OSSD)
- Photoelectric sensor (OSSD)
Safety input 2
13-16
Safety input 3
21-24
Safety input 4
29-32
Safety output 1
1, 25
Switching dependent on
- Safety input 1-4
- Logic
- Switch-on/switch-off delay (optional)
- Contactor/start inputs (optional)
Safety output 2
2, 26
Safety output 3
3, 27
Safety output 4
4, 28
External contactor/
Start 1-2
11, 12
External contactor and/or start button
(automatic, manual or monitored)
Operating voltage
9, 10
Control output 1
17
Not suitable for safety functions!
Switching dependent on
- Safety input 1-4
- Logic
- Switch-on/switch-off delay times
(optional)
Control output 2
18
Control output 3
19
Control output 4
20
Danger
Danger of electrocution!
Ensure that the safety control unit is installed and put into
operation only by specially trained, authorized personnel.
NOTE
Make sure that no external voltage is applied to the safety
inputs when the operating voltage is applied (e.g. by devic-
es with OSSD outputs).
12 Maintenance
Each safety circuit must be checked by specially trained, authorised personnel
in accordance with national regulations within the time-limits specified therein.
(Recommendation: in accordance with application as per EN ISO 14119)
13 Troubleshooting
- If the ready LED and the LEDs of the applied inputs light up, the outputs flash
and the error LED is off, then the safety control unit is waiting for the start
signal at input "ext. contactor /start" (
see also item 13 "Troubleshooting"
).
NOTE
Upon initial commissioning of a safety control unit with a
new configuration, complete validation according to the rel-
evant standards must be carried out.
LEDs eloFlex
Meaning
Remedy
Ready
Error
I1
I2
I3
I4
O1
O2
O3
O4
Normal operation —
Operating time
exceeded, only
affected input(s)
will flash
Open and close
the door. If error
persists, replace
the sensor/
switching device
Internal fault
Apply the supply
voltage again².
If error persists,
replace switching
device
1
1
Input(s)
available, start
expected
Check the
feedback loop:
Is the start signal
at the input start
1/2 (terminal 11/
12) available?
14 Disposal
Dispose of packaging and used parts in accordance with the regulations of the
country in which the device is installed.