background image

 

 

General safety 

  Use only as directed in the operating instructions provided.

 

  The unit should not be used if it has encountered a physical shock or has been dropped.

 

  The unit must be stored and transported in a horizontal position (see package label).

 

  After transport or storage allow the unit to dry out (2-3 hrs.) before connecting to mains power.

 

  Use only original accessories provided by the manufacturer and ordered 

specifically for this model.

 

 

Electrical safety 

  Connect to the mains only with a voltage corresponding to that on the serial number label.

 

  Ensure that the switch and plug are easily accessible during use.

 

  Do not plug the unit into the main outlet without grounding, and do not use extension lead without 

grounding.

 

  Before moving the unit, disconnect it from the mains. To turn off the unit, disconnect the power plug 

from the mains outlet.

 

  It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt on 

or inside the equipment. If liquid is split inside the unit, disconnect it from the mains and have it 
checked by a competent person.

 

During operation 

  Do not block the platform movement.

 

  Do not leave the operating unit unattended.

 

  Do not operate the unit in environments with aggressive or explosive chemical mixtures.

 

  Do not operate the unit if it is faulty or been incorrectly installed.

 

  For indoor use only.

 

  Before using any cleaning or decontamination method except those recommended by the manufacturer, 

check with the manufacturer that the proposed method will not damage the equipment.

 

  Do not make modifications to the unit.

 

Biological safety 

  It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt 

on or inside the equipment.

 

 

Preparation to use 

  Unpack the device. Please keep the packaging material for transportation or storage purposes.

 

  If the machine was stored at a temperature below 0°C, make sure that it is kept at room 

temperature for at least two hours before turning it on.

 

  Place the shaker onto a level, horizontal surface.

 

  Examine the power adapter and appearance of device for damage.

 

  Connect the power cord to the centrifuge, insert the adapter in to the socket and press network 

switch at ( I ) symbol. Display will light up on the control panel.

 

  Check the platform. Try rotating it by hand. There should be no noise or obstacles to smooth 

running.

 

  Check the surrounding of device. Safety distance of 30cm must be observed around the device 

during operation.

 

  Check for other signs of damage or malfunction.

 

 

ATTENTION! 

If there is any apparent damage or malfunction, DO NOT TURN ON the shaker 

without consulting a specialist. 

Summary of Contents for DOS-20L

Page 1: ...User manual Digital orbital shaker DOS 20L ELMI Ltd 21 133 Aizkraukles Str Riga LV 1006 Latvia T 371 67558743 T 371 67551934 E info elmi tech com W www elmi tech com...

Page 2: ...device 4 Control description 5 Using the device main menu 6 Orbital rotation mode 7 Auto reverse mode 7 Reciprocal mode 8 Vibration mode 8 Programming menu 9 10 Additional modes 11 Disinfection and cl...

Page 3: ...hes flasks Petri dishes etc Technical specifications Size of working platform mm 415 295 Speed of rotation RPM 10 300 Amplitude of platform movement mm 20 Maximum load kg 7 Working modes 4 Type of pla...

Page 4: ...ironments with aggressive or explosive chemical mixtures Do not operate the unit if it is faulty or been incorrectly installed For indoor use only Before using any cleaning or decontamination method e...

Page 5: ...4 1 Network switch 2 Power plug 3 Working platform 4 Casing 5 Control panel 3 4 1 2 5...

Page 6: ...ight navigation keys and increasing decreasing parameter value keys Entering and exiting key in programming mode to set the step parameter Start Stop key Setting key to manage the interface of device...

Page 7: ...Reciprocal 4 Vibration To choose a mode go to the lowest level of the main menu and select the desired mode using the right or left navigation keys Adjusting the parameters of the mode Using the navig...

Page 8: ...ters TIMER 1 minute 99 59 minutes continuous mode PRM 15 300 Auto reverse mode Auto reverse mode platform orbital motion mode with set and equal numbers of clockwise and counter clockwise turns Adjust...

Page 9: ...and operating time Options TIMER 1 minute 99 59 minutes continuos mode RPM 07 20 Angle 10 360 Vibration mode Vibration mode reciprocating type of movement of the platform imitating shake Ability to cu...

Page 10: ...ogramming menu Ranges are from 1 to 99 or continuos mode can be used Create a custom cycle program by adding four steps and a number of program repeat cycles as required All settings are made using th...

Page 11: ...tep menu s bottom line and select the pause mode set the time to 1 minute and press ENTER key 3 Select the 3rd step and press ENTER key 3 1 Go to the step menu s bottom line and select orbital rotatio...

Page 12: ...he PROGRAM key and switching the network switch off and on again To return to the advanced menu repeat the operation Interface adjustment menu In the interface menu you can adjust the display brightne...

Page 13: ...n 80 and temperature range of 10 C up to 40 C It is not recommended to store the equipment more than 36 month Warranty statements Warranty applies to 24 month period from the date of purchasing Malfun...

Page 14: ...ry for this class of device Quality control person name signature Date of manufacture Place for stamp Certificate of sale Organization Address Phone Vendor name signature Date of sale Manufacturers ad...

Page 15: ...14 Video instruction is available youtube com elmimedia videos ELMI Ltd 21 133 Aizkraukles Str Riga LV 1006 Latvia T 371 6755 8743 T 371 6755 1934 E info elmi tech com W www elmi tech com...

Reviews: