- 4 -
3. Emergency arming & disarming alarm from CBP32 panel buttons
This operating method is not recommended as requires opening the control panel cabinet.
Nevertheless, in case of emergency, e.g. no access to system registered phone or lost re-
mote, there are two possible methods of system arming/disarming using the panel buttons:
1.
If “day/night” mode is set OFF (see pt. 8.5 menu) - by entering user’s password (by default:
▲▲▲▲) followed by OK will arm the system or, disarm the system if it was armed. Exit delay
time counts down starts prior to system is armed.
2. If “day/night” mode is set ON (see pt. 8.5 menu) - by entering user’s password followed by
OK will allow selection of one of four methods of system arming:
“
▲
-
disarm”
-
disarming the alarm system
– “disarmed” status appears on dis-
play. Anti-sabotage zones
“24h” remain armed.
“
◄
-
arm”
-
arming the system. On the end of the exit delay (signalled acoustically and
optically with displayed time countdown on the LCD panel), all alarm zones ex-
cept blocked are armed
. “Armed” status appears on display.
“
►
-
day”
-
partial arming in day supervision mode. The zones earlier define
d as “day
armed” and the “24h” zones are armed (as in pt. 3.1). The “day mode” message
appears on display.
“
▼
-
night”
-
partial arming in night supervision mode. At the end of exit delay (signalled
acoustically and optically) all alarm zones are armed, except for blocked zones
and zones
earlier defined as „night disabled” (as in pt. 3.1.). The “night armed”
message appears on display.
Arming the system bypassing selected alarm zones.
If, in the course of arming the system, one of the zones is violated, the reaction of the system
depends on whether the zone was earlier defined as “bypass” type (see pt. 3.1.g) or not:
-
if the zone function is defined as
“bypass” (Y) – the system generates 3 beeps on arm-
ing using remote
or panel buttons and waits 8 seconds for user’s decision whether to
arm the system bypassing violated zone. Acceptance with the use of remote or panel
OK button arms the system bypassing that zone. If no action is detected (>8s) arming
procedure is cancelled. Arming with the use of mobile phone will arm the system and
SMS notification will be send informing of the bypassed zone.
-
if the zone is not defined as
“bypass” type (N) – the system generates 3 beeps on arm-
ing using remote and will not arm. When arming using panel buttons displays message
“Violated zones” with zone name and system will not arm. In that case, the cause of the
zone violation should be cleared and a new arming should be made. While arming by
mobile phone, the system will respond by sending SMS with information on violated
zones.
See also S.S. pt. 9
– “System arming signalling modes”
CBP32 SELECTED FUNCTIONS DESCRIPTION
Alarm zones monitor
CBP32 control panel allows checking operation of all detectors by displaying all alarm zones
simultaneously. To activate this function but
ton “◄” must be pressed and hold down until two
16 bar graph lines scale appear on the LCD panel displaying status of all 32 alarm zones of
the CBP32 control panel. Any violated zone
produces “*” mark (star) to be momentarily dis-
played on the LCD at dot position corresponding to zone number in which violation was de-
tected. Sabotage activation displays
mark “S”. Function deactivation is made by “◄” button.