- 11 -
remote to the control panel, the last button must be used while learning the remote, i.e. sec-
ond or fourth. Operation mode of the remote can be set on in pt. 5.7 of Service Settings.
5.4. Disabling user.
Service Settings
→ System Users → Disabling user
Please follow detailed instructions as in “Zone disabling” menu (S.S. pt. 3.4). After disabling a
user, its remote and password are inactive.
In order to disable user’s control of CBP32 panel
by SMS or CLIP, the functions should be set off in pt. 5.6.9 and pt. 5.6.10 of S.S.
5.5. Mobile phone number.
Service Settings
→ System Users → Phone number
This menu allows entering
user’s mobile phone number. The number must be preceded by
national dialling code number,
without the “+” sign. Example: 33xxxxxxxxx for France.
5.6. Mobile phone functions.
Service Settings
→ System Users → Phone functions
This menu allows selection (Y/N) of notifications, messages, commends and SMS/CLIP func-
tions required to be active operating CBP32
control panel with user’s GSM phone:
1) SMS on alarm
- sending SMS on alarm set on;
2) SMS on arming
- sending SMS
to control panel phone number: “arm” to arm and
“disarm” to disarm alarm system;
3) SMS on powering
- sending SMS on mains power failure and return;
4) SMS on radio link off - sending SMS on radio link failure;
5) SMS on low battery
- sending SMS on low battery;
6) SMS on other failures - sending SMS on other failures (e.g. accumulator failure);
7) Alarm CLIP
- making alarm CLIP call;
8) Descriptive SMS <-> SMS with ID codes
– selection of SMS content: event description
such as “Intruder Alarm” or the use of special codes defined in pt. 7.9, 7.10 and 7.11.7.
9) SMS accept
- SMS commands (as below) acceptance received by CBP32.
ARM, DISARM, NIGHT and DAY- sets appropriate arming mode;
DISABLE zone_name - disables zone: zone_name;
ENABLE zone_name - enable zone: zone_name;
STATUS
- in response control panel sends SMS on current armed/disarmed
status and failure events;
TIME HH:MM
- sets current time in control panel;
TEST
- sets up instant test procedure and starts time count to next test
under condition that
“Test every time interval” is selected in pt.
7.11
.2 and “Execute test” function is selected in pt. 5.6.12.
LAMP
- sample control command for output named LAMP. Detailed de-
scription of controlling outputs by SMS commands can be found
in pt. 4.1.
10) CLIP arming - remotely arming and disarming CBP32 pane by CLIP call (by calling the
panel phone number). Panel is disarmed if call is rejected after one ring. If
the call is rejected after three rings, the panel is armed.
11) Call back - calling back function. If the control panel is called by user/operator, it will call
back. This and next function may be used in operation with monitoring centre:
a) if the function is set off, CBP32 panel rejects the call after 3-4 seconds and
does not call back to calling number,
b) if the function is set on, the control panel rejects the call and calls back.
12) Execute test - executing SMS or CLIP time interval test by CBP32 panel. The function
may be used in operation with monitoring centre. See also pt. 7.6, pt. 7.7
and pt. 7.11 of Alarm Notification by GSM section.