- 14 -
send ID codes instead of standard text notification, e.g.
“Intruder alarm: kitchen”, option “SMS
with I
D codes” must be selected in S.S. pt. 5.6.8.
7.10.
Definition of monitoring station subscriber account number .
Service Settings
→ GSM monitoring → Subscriber account number
This menu is used to define subscriber code (max. 8 characters) used by monitoring station
operating in e.g. “Ademco Contact ID” to identify SMS notification sender (see pt. 7.11.7).
7.11. Auxiliary GSM settings.
Service Settings
→ GSM Functions → Aux GSM settings
1) Test as CLIP or Test as SMS
- interval test as CLIP call (default) or SMS.
2) Execute test at time or Execute test after interval - test executed daily at predefined test
time (default), or test after predefined time interval.
3) SMS with password - if Y SMS send to CBP32 must begin with password (default N).
4) Letter case sensitive - N (no) (default). If selected Y (yes), the control panel is SMS letters
case sensitive.
5) Alarm CLIP once - if this function is set off (default), control panel expects CLIP notification
rejection. If the call (see pt. 7.4) is not rejected, the panel disconnects and repeats CLIP
call twice. If the function is set on (Y), CLIP calling is made once only, even the call is
not rejected. It does not refer to a control CLIP that is made only once as standard.
6) Use default SMS centre no or Use entered SMS centre no
– selection of the first option
(default) allows CBP32 panel to use SMS centre number supplied with SIM card, while
selection of the second option causes CBP32 to use centre number entered in pt. 7.1.
7) Ademco Contact ID
→ Subs event code → Subs event code + zone no
The settings is valid only, if “SMS with ID codes” is set on in pt. 5.6.8 and allows selection
of one of three SMS notification patterns send to monitoring station:
1) ”Ademco Contact ID” pattern. SMS notification has the following form:
CCCCQEEEGGZZZ
where “CCCC” stands for subscriber code set in pt. 7.10. Other elements are defined by
the user, e.g. three digits event number “EEE”. NOTE: if monitoring station requires digits
“18” to appear before “CCCC” then subscriber’s code should input as “18CCCC” in
pt.7.10.
2) ”Subs event code” pattern. SMS notification has the following form:
CCCCEE
where CCCC stands for subscriber code set in pt. 7.10 and “EE” event code set in pt.7.9.
3) ”Subs event code + zone no” pattern. SMS notification has the following form:
CCCCEEZZ
where CCCC is subscriber, “EE” event code and end “ZZ” is zone or user number.
8. Auxiliary functions settings.
This menu contains auxiliary functions and options for alarm system configuration.
Use ▲▼
buttons to browse
between functions and ◄► buttons to change setting. OK button saves se-
lection. Exit menu any time with C button without saving selections.
8.1. Jamming protection (default N)
Service Settings
→ Aux functions → Jamming protection
This function allows radio jamming anti-sabotage protection of wireless alarm system. If se-
lected (Y), it will activate sabotage alarm in zone 30 on all deliberate or incidental jamming in
used radio band.