QUARTZ Range 
External Sounder 

Models

 

QUARTZ-1000-G2, QUARTZ-3000-G2 

 

F

EATURES

 

 

 

-

 

High Efficiency Operation  

-17mA standby, 
-130mA sounding 

-

 

Silent Engineer Start-up 

-

 

 Selectable sound auto cut=off timer 

-

 

Selectable SAB or SCB operating mode 

-

 

Integral 1 Watt Xenon tube strobe 

-

 

Active inrush current limit on strobe 

-

 

Strobe Power Save Mode 

-

 

Flashing Comfort LEDs 

-

 

Microprocessor controller 

-

 

Enclosed electronics module 

 

 

 

 

 

              

 

Elmdene International Ltd

 

 

Tel:  +44(0)23 9269 6638 

3 Keel Close, Interchange Park, 

 

Fax:  +44(0)23 9266 0483 

Portsmouth, Hampshire, PO3 5QD, UK 

Web:   

www.elmdene.co.uk

 

Summary of Contents for QUARTZ-1000-G2

Page 1: ...ounding Silent Engineer Start up Selectable sound auto cut off timer Selectable SAB or SCB operating mode Integral 1 Watt Xenon tube strobe Active inrush current limit on strobe Strobe Power Save Mode...

Page 2: ...he TS Tamper Source will normally be connected to the TR Tamper Return of the next sounder except for the last unit which will have TS linked to H See Fig 3 Engineer Mode This selects silent start up...

Page 3: ...ation or maintenance In engineer test mode apply a positive signal to prevent self activation of siren by tamper condition e g lid open H Permanent positive hold off supply H Permanent negative hold o...

Page 4: ...8 Option 3 PAK200360 Iss 03B Mar 2012 2012 ELMDENE INTERNATIONAL LTD Fig 2 Single Quartz Tamper Connection ENG H H TS TR R ST TAMP IN ST R H H TS ST TR R H H ENG CONTROL PANEL UNIT 1 UNIT 2 Fig 3 Mult...

Page 5: ...holes as required for fixing the backplate to the wall and for cable entry to the rear of the unit 3 Fit tamper extender if required and trim to desired length 4 Route cable from control panel throug...

Page 6: ...store H 17 Disconnect H and check that the siren activates Restore H 18 Commissioning complete MAINTENANCE The Quartz sounder should be tested for correct operation on a periodic basis A minimum of on...

Page 7: ...sounders on one tamper loop Cover or Rear tamper switch not closed Check cover and rear tamper switches fully closed DISPOSAL OF PRODUCT AT END OF LIFE This product falls within the scope of EU Direc...

Page 8: ...Ni MH Voltage 6 0V Capacity 320 mAH Strobe Rating 1 Watt Flash Rate 1 Hz reduces to 1 2 Hz after 15 minutes Comfort LEDs Alternate flash 60 per minute Material 3mm Polycarbonate all parts Tamper Detec...