background image

 

 

Technical Support Line +44 (0)23 9269 6638 (Option 3) POE-MINIPOD          PAK200793_01A Nov 2016             © 2016 Elmdene International Ltd 

 
 

O

PERATING 

I

NSTRUCTIONS

 

 

 

In the event of loss of PoE+ to the PoE-MINIPOD, the Fault signal contacts will open and the POE-MINIPOD will continue 
to deliver up to 14W PoE802.3at for up to 4 hours (dependant on charge state or capacity of battery) 
If the output of the POE-MINIPOD fails, the cause of the failure should be investigated e.g. short circuit load, connection 
of a deeply discharged battery. The fault should be rectified before restoring power to the POE-MINIPOD. If any of the 
fuses require replacing, ensure the correct fuse rating and type is used.

 

M

AINTENANCE

 

 

 

This unit is intended for use by Service Personnel only.  There are NO USER SERVICEABLE parts inside. 
There  is  no  regular  maintenance  required  of  the  POE-MINIPOD  other  than  periodic  testing,  and  replacement  of  the 
standby  battery.   

Reference  should  be  made  to  the  battery  manufacturer's  documentation  to  determine 

typical/expected battery life with a view to periodic replacement of the battery.  
 

C

OMPLIANCE

 

 

 

This power supply unit meets the essential requirements of the following European Directives: 

 
Low Voltage 

 2014/35/EU 

EMC  

 

 2014/30/EU  

   

WEEE 

 

 2012/19/EU         

RoHs2  

 

 2011/65/EU 

 
 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 

This  product  falls  within  the  scope  of  EU  Directives  2012/19/EU  Waste  Electrical  and  Electronic 
Equipment (WEEE) and 2013/56/EU (Battery). At the end of life, the product must be separated from 
the  domestic  waste  stream  and  disposed  via  an  appropriate  approved  WEEE  disposal  route  in 
accordance with all national and local regulations. 
Before  disposal  of  the  product,  any  batteries  must  be  removed,  and  disposed  separately  via  an 
appropriate  approved  battery  disposal  route  in  accordance  with  all  national  and  local  regulations. 
Package used batteries safely for onward transport to your supplier, collection point or disposal facility. 

 

Caution:  Risk of fire or explosion  

if bare battery wires are allowed to touch. 

 

See Specification for battery type information. The battery is marked with the crossed out wheelie bin 
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). 

For more information see: 

www.recyclethis.info

 

 

 
 
 
 
 
 
 
 
 
 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly.

 

Reviews: