Symptom
Fault
Action
Sounder activated in non-alarm condition
and tamper shows at panel
Cover not closed correctly.
Check cover closed and screw secure.
Cannot SET control panel
(due to sounder tamper)
Cover or Rear tamper switch not
closed.
Check cover and rear tamper switches fully closed.
No H+/H- connection
Check power available on H+/H- connections
D
ISPOSAL OF
P
RODUCT AT
E
ND OF
L
IFE
This product falls within the scope of EU Directives 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) and 2006/66/CE
(Battery). At the end of life, the product must be separated from the domestic waste stream and disposed via an appropriate approved
WEEE disposal route in accordance with all national and local regulations.
Before disposal of the product, the SAB battery must be removed and disposed of separately via an appropriate approved battery disposal
route in accordance with all national and local regulations. Package used batteries safely for onward transport to your supplier, collection
point or disposal facility.
Caution risk of fire or explosion if bare battery wires are allowed to touch.
See Specification for battery type information. The battery is marked with the crossed out wheelie bin symbol, which may include lettering
to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
For more information see:
www.recyclethis.info
S
PECIFICATION
Siren Output
110dBA peak @ 1m.
Power supply
10.0 – 14.0V dc, 12V dc nominal
Current Consumption
15mA standby
220mA maximum when sounding.
65mA maximum when strobing.
Cut-off Timer
Selectable 15 minutes or no cut-off.
SAB Facility
1 x 6V 170mAh NiCd battery, trickle charged from H+ supply
Case Dimensions
160mm x 110mm x 40mm.
C
OMPLIANCE
This product meets the essential requirements of the following EU Directives:
EMC:
2004/108/EC
RoHS:
2002/95/EC
WEEE:
2002/96/EC
Battery:
2006/66/EC
EN50131-4:2009
INT500
Security Grade 3
INT500S
Security Grade 2
Environmental Class II
This product is suitable for use in systems designed to comply with PD6662:2010 at:
Grade 2 (INT500S) or Grade 3 (INT500) and Environmental Class II.