3
Technical Support: +44(0)23 9269 6638 (option 3)
PAK200033_05A Jan 2012 ©2012 ELMDENE INTERNATIONAL LTD
7)
Connect R- to Ring or Bell output of the control panel and ST- to Strobe output (if required) .
8)
If Negative Tamper Return is used, connect RTN to Negative Tamper return on the control panel.
9)
If Lo facility is used, connect M- to Keypad Follow or a programmable output from the control panel
10)
For SAB facility (INT500S only) connect the battery wires to BAT+ and BAT-, ensuring correct polarity.
NOTE: The unit will sound until the cover is replaced.
T
ESTING
WARNING:
HIGH
VOLTAGE
–
D
O
NOT
TOUCH THE
PCB
COMPONENTS WHILE THE STROBE IS
OPERATING
(
OR FOR AT LEAST
1
MINUTE AFTER STROBE SUPPLY IS REMOVED
).
1)
Activate bell or ring output from control panel (R- to 0V). Check high volume sound activates.
2)
Activate strobe output from control panel (ST- to 0V). Check the strobe activates.
3)
If Lo facility is used, activate keypad on control panel and check low volume from sounder. Adjust VR1
for desired Lo volume level.
4)
Remove cover and check high volume from sounder. (Tamper activation)
5)
If Negative Tamper Return connection is made to the control panel, check that the panel has detected
a tamper condition from step 2)
6)
Replace the cover. Check that the sounder switches off and the tamper output has cleared.
7)
INT500S: Remove H+ supply connection at the control panel. Check high volume from sounder and
tamper or bell failure is detected at the control panel.
8)
INT500S: Replace H+ supply. Check that the sounder switches off and the tamper output has cleared.
9)
Fasten the cover to the backplate using the fixing screw supplied.
M
AINTENANCE
This sounder should be tested for correct operation on a periodic basis. A minimum of one check every 12
months is recommended. The following features should be verified on each maintenance visit:
1)
Correct operation of sounder from control panel signals
2)
Correct operation of cover and rear tampers.
3)
Remove the +ve power supply from the control panel and check internal battery voltage as
measured between BAT+ and BAT- is greater than 4.5V dc. If the battery voltage is less than this
value replace internal battery with similar of 6V 170mAh rating.
4)
Check for signs of significant dust ingress. Clean as necessary.
SAB
B
ATTERY
R
EMOVAL
The SAB battery may be removed for disposal at end of product life. To remove the battery, disconnect
red and black leads from BAT+ and BAT- and unclip battery from holder. To fit a new battery, clip into
holder and reconnect positive (RED) lead to BAT+ and negative (BLACK) lead to BAT-.
IMPORTANT: Ensure correct polarity of connections and that exposed battery leads DO NOT accidentally
touch.
Dispose of used batteries in accordance with all national and local regulations