background image

4

 

 

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

  PAK200032_05A   Jan 2012                        ©2012 ELMDENE INTERNATIONAL LTD  

 

 

F

AULT 

F

INDING

 

 

 

Symptom 

Fault 

Action 

Sounder activated in non-alarm condition 
and tamper shows at panel 

Cover not closed correctly. 
 

Check cover closed and screw secure. 
 

Cannot SET control panel 
(due to sounder tamper) 

Cover or Rear tamper switch not 
closed. 

Check cover and rear tamper switches fully closed. 

No H+/H- connection 

Check power available on H+/H- connections 

 

D

ISPOSAL OF 

P

RODUCT AT 

E

ND OF 

L

IFE

 

 

 

This product falls within the scope of EU Directives 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) and 
2006/66/CE (Battery). At the end of life, the product must be separated from the domestic waste stream and disposed 
via an appropriate approved WEEE disposal route in accordance with all national and local regulations. 
 
Before disposal of the product, the SAB battery must be removed and disposed of separately via an appropriate 
approved battery disposal route in accordance with all national and local regulations. Package used batteries safely for 
onward transport to your supplier, collection point or disposal facility. 

Caution risk of fire or explosion if bare battery wires are allowed to touch. 

 
See Specification for battery type information. The battery is marked with the crossed out wheelie bin symbol, which 
may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).  

For more information see: 

www.recyclethis.info

 

 

S

PECIFICATION

 

 

 

Siren Output 

 

 

110dBA peak @ 1m 

Power supply 

 

 

10.0 – 14.0V dc, 12V dc nominal 

Current Consumption 

 

45mA standby 

 

 

 

 

260mA maximum when sounding. 

Cut-off Timer 

 

 

Selectable 15 minutes or no cut-off. 

SAB Facility 

 

 

1 x 6V 170mAh NiCd battery, trickle charged from H+ supply 

Ring Line Monitoring 

 

R- input connected to H+ via 1K0 resistor. R- pulled to H- when 

 

 

 

 

front or rear tamper switch is activated. 

Case Dimensions   

 

160mm x 110mm x 40mm. 

 

C

OMPLIANCE

 

 

 

This product meets the essential requirements of the following EU Directives: 

EMC: 

2004/108/EC 

RoHS: 

2002/95/EC 

WEEE: 

2002/96/EC 

Battery: 

2006/66/EC 

 

EN50131-4:2009 

INT400 

Security Grade 3 

 

 

INT400S 

Security Grade 2 

 

Environmental Class II 

 

This product is suitable for use in systems designed to comply with PD6662:2010 at: 

Grade 2 (INT400S) or Grade 3 (INT400) and Environmental Class II.

 

 

The packaging supplied with this product may be recycled. 

 Please dispose of packaging accordingly.

 