background image

2

 

 

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

  PAK200032_05A   Jan 2012                        ©2012 ELMDENE INTERNATIONAL LTD  

 

The tamper return output to the control may be configured using link JP1 jumper for either: 

-

 

Switched output: 

Tied to 0V in tamper non-active condition. 

 

 

 

 

HIGH (6.0 - 7.5V) in tamper active condition 

-

 

Open collector output:   Pulled to 0V when in non-tamper state 

 
 
 

M

ODE 

S

ELECTION

 

 

 
 
 
 
 
 

 
JP1 

Negative tamper enable. 

 

Link pins 1 & 2 for switched output (default). 

 

Link pins 2 & 3 for open collector o/p 

JP2 

Cut-off timer. 

 

Link = no cut-off (default) 

 

No link = sounder cut-off after 15 minutes 
 

Figure 1.0 Connections and Jumper Link Options 

 

S

OUND 

C

UT

-O

FF 

T

IMER

 

 

 

With the cut-off timer link NOT fitted, the 

INT400(S)

 sounder will automatically stop sounding after 15 

minutes, irrespective of the status of the sound trigger (R-) input.  

 

SAB

 

M

ODE 

(INT400S

 

O

NLY

 

 

SAB mode is enabled if the internal battery is connected. The siren will self-activate if either of the 
tampers are activated.  The INT400S will also self-activate if the supply lines are cut. 

 

C

ONNECTIONS

 

 

 

R-

 

Negative siren trigger. Apply 0V to activate sounder 

H+

 

Permanent positive hold-off supply, +12Vdc nominal 

H-

 

Permanent negative hold-off supply 

BAT-

  SAB Battery negative

  

BAT+

  SAB Battery positive

 

RTN

  Negative tamper return. 

R-    H+   H-  BAT- BAT+ RTN 

JP1 

JP2

 

1  2  3

 

Reviews: