background image

3

 

 

 

 

Technical Support: +44(0)23 9269 6638 (option 3) 

  PAK200032_05A   Jan 2012                        ©2012 ELMDENE INTERNATIONAL LTD  

 

 

C

OMMISSIONING

 

 

 

1) 

Remove cover. 

 

2) 

Offer backplate to desired position on 
mounting surface and drill holes to match 
chosen fixing centres. 

3) 

Fix backplate to mounting surface using 
appropriate fixings for the mounting surface. 

4) 

Set the required Cut-off Timer and Tamper Return options using JP1 and JP2. 

5) 

Loop the connection cable three times through the supplied ferrite as shown. 

6) 

C12V dc and 0V supply from the control panel to H+ and H- respectively. 

7) 

Connect R- to Ring or Bell output of the control panel.

 

8) 

If Negative Tamper Return is used, connect RTN to Negative Tamper  return on the control panel.

 

9) 

For SAB facility (INT400S only) connect the battery wires to BAT+ and BAT-, ensuring correct 
polarity. 

 

NOTE: The unit will sound until the cover is replaced. 

10) 

Replace cover temporarily. Sounder will silence when cover completely replaced. 

 

T

ESTING

 

 

 

1) 

Activate bell or ring output from control panel (R- to 0V). Check high volume sound activates. 

2) 

Remove cover and check high volume from sounder. (Tamper activation) 

3) 

If Negative Tamper Return connection is made to the control panel, check that the panel has 
detected a tamper condition from step 2) 

4) 

If Ring Line Monitoring facility is used on the control panel, check that the panel detects a tamper or 
bell failure. 

5) 

Replace the cover. Check that the sounder switches off and the tamper output has cleared. 

6) 

INT400S: Remove H+ supply connection at the control panel. Check high volume from sounder and 
tamper or bell failure is detected at the control panel. 

7) 

INT400S: Replace H+ supply. Check that the sounder switches off and the tamper output has 
cleared. 

8) 

Fasten the cover to the backplate using the fixing screw supplied. 

 

M

AINTENANCE

 

 

 

This sounder should be tested for correct operation on a periodic basis. A minimum of one check every 12 
months is recommended. The following features should be verified on each maintenance visit:

 

1) 

Correct operation of sounder from control panel signals

 

2) 

Correct operation of cover and rear tampers.

 

3) 

Remove the +ve power supply from the control panel and check internal battery voltage as 
measured between BAT+ and BAT- is greater than 4.5V dc. If the battery voltage is less than this 
value replace internal battery with similar of 6V 170mAh rating.

 

4) 

Check for signs of significant dust ingress. Clean as necessary.

 

 

SAB

 

B

ATTERY 

R

EMOVAL

 

 

 

The SAB battery may be removed for disposal at end of product life. To remove the battery, disconnect red and black 
leads from BAT+ and BAT- and unclip battery from holder. To fit a new battery, clip into holder and reconnect positive 
(RED) lead to BAT+ and negative (BLACK) lead to BAT-. 
IMPORTANT: Ensure correct polarity of connections and that exposed battery leads DO NOT accidentally touch. 

Dispose of used batteries in accordance with all national and local regulations 