Sagab by Elma 911
24
2
4
10A
5
3
μ
COM
every
15 min.
MAX
¦ ¸
V
AUTO
Ω
7
V
V
6
Mode
1
DC
AC
8
C F
μ
9
Range
MAX
C
F
SAFETY SYMBOLS
This symbol adjacent to another symbol, terminal or operating device
indicates that the operator must refer to an explanation in the Operating
Instructions to avoid personal injury or damage to the meter.
This
WARNING
symbol indicates a potentially hazardous situation, which if
not avoided, could result in death or serious injury.
This
CAUTION
symbol indicates a potentially hazardous situation, which if
not avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds (in this case) 500 VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being
associated with ranges that may, in normal use, be subjected to particularly
hazardous voltages. For maximum safety, the meter and its test leads should
not be handled when these terminals are energized.
CONTROLS AND JACKS
1.
2000 count Liquid Crystal Display with symbolic signs
2.
Function switch
3.
Positive input jack
4.
COM (negative) input jack
5.
10A (positive) input jack for 10A DC or AC measurements
6.
Mode pushbutton: selection Continuity/Diode, AC/DC, Temperature(C/F)
7.
Range pushbutton
8.
Data Hold pushbutton
9.
MAX. Hold pushbutton
Input Limits
Function
Maximum Input
V DC or V AC
CATII-1000V DC /AC
CATIII-600V DC /AC
mA DC/AC
200mA DC/AC
A DC/AC
10A DC/AC (30
seconds max every
15 minutes)
Resistance,
Diode test,
Continuity
Temperature
500V DC/AC
WARNI
NG
CAUTI
ON
MAX
500
V