Before the initial commissioning
© Elma Schmidbauer GmbH
BA_Elmasolvex_SE_EN_Vers. 03.2018
19
4
Before the initial commissioning
4.1
Unpacking and installing the cleaning machine
Keep the packaging for possible service purposes. Any disposal
must be made in accordance with the applicable disposal
regulations. You can also send the packaging back to the
manufacturer or supplier.
Inspect the cleaning machine for possible transport damage
before the first start-up. The cleaning machine must not be put
into operation in the case of recognisable damage. Contact
your supplier and the carrier.
Place the cleaning machine for operation on a stable, level, dry
base which is resistant to the cleaning liquid. A smooth
installation surface is required to be able to rotate the cleaning
machine when changing the cleaning liquid.
Remove the foam transport locks and keep these if necessary.
Danger of electric shock due to ingress of liquid!
Protect the cleaning machine against the ingress of moisture.
The interior of the cleaning machine is protected against
dripping moisture from outside (IP class 20).
However, keep the installation surface and the case dry to
prevent electrical accidents and damage to the cleaning
machine.
Provide sufficient ventilation at the location of the cleaning
machine.
In the case of intended use of flammable solvent-based media,
4 air changes
1)
per hour and per cleaning machine using
technical ventilation measures must be guaranteed for the
explosion-safe operation of the cleaning machine(s).
1)
must be realised by correctly designed technical ventilation installed
on the building side (e.g. suitable exhaust air blower into the open air).
The following additional requirements must be met for safe
operation of this cleaning machine:
•
Permitted ambient temperature in operation: +5 °C - +30 °C
•
Permitted relative humidity in operation: max. 80%
•
The surroundings must not have high dust levels
Fire and explosion hazard!
Ignitable vapours of the cleaning and rinsing media can escape
in the case of improper operation without exhaust air tube and
when changing the cleaning liquids.
Smoking and open ignition sources are prohibited in the
machine surroundings.
Packaging
Inspection for
transport damage
Installation surface
Removing transport locks
DANGER
Ambient conditions
DANGER