background image

the tester.
3. Press TEST key.
The tests are performed depend on whether a remote identifier 
unit (ID) is connected to the end of the cable or not.

FAILURES DETECTED NO remote unit

with remote unit

Short

Open (nearend)

Open (farend)

Length

Split pair

Mis wire

For twisted pair cables, when the tester checks for a cable 
remote identifier unit (ID) at the other end of the cable and a 
pass condition exists, the LCD will display the following 
information.

m

 

m

 

If testing coaxial cable with a termination, the tester dispalys 
the total resistance of the cable wires and the terminetion.

COAX        ST  = 49.0 

Ω

Only coaxial cables must be unterminated for the tester to 
display the cable’s length.  If a coaxial cable is open looks just 
like an unterminated cable, then a length measurement that is 
less than the known cable length would indicate a possible 
open in the cable.
The tester if a failure is detected, additional information can be 
viewed with the ▼/ ▲keys.  The failure messages refer to 
individval wires rather than pairs of wires.  The TEST mode 
failure messages are described in following tables.

Tes

t failures (without remote unit)

FAILURE

DISPLAY

DESCRIPTION

Short 
(UTP/FTP)

m

Display shorted wires and 
most likely distance to the 
short.

OPEN

m

Display open wires and the 
open whether it is at the near 
or far end of the cable.

Split Pair

Display wire pairings that are 
incorrect based on the cable 
selected.

A short greater than 0

Ω

, will cause display a length greater 

than the actual distance to the short.  The tester uses 0

Ω

 to 

calculate distance to a short.

Good cable, cable remote unit ID#1 
detected.

Good cable, no cable remote unit 
detected or the tester may not 
sense the remote unit.

Summary of Contents for 46

Page 1: ...t also tests up to 8 different cables at one end A stored cable library provides quick access to common cable types U S Pat No Des 446 135 The Cable Tester comes with One remote identifier 1 RID46 234 Optional for 2 3 4 RID46 5678 Optional for 5 6 7 8 One patch cable RJ 45 to RJ 45 30 cm long RJ45 RJ45 female coupler connector Instruction manual Carrying case 6 pcs AAA 1 5V Battery CAUTION The tes...

Page 2: ... split pairs keys Scroll through a selection of choices or multiple displays ENTER key Enter a selection into the test tool and move to the next setting selection M Memory R Read key Data memory and read 99 sets RJ45 jack Standard 8 pin modular jack for connecting UTP and FTP cable 11 Remote Identifiers 1 8 12 BNC connect for connecting coaxial cables III SPECIFICATIONS Cable Length Measurements R...

Page 3: ...60 70 RH Dimensions Cable Tester 150 x 72 x 35mm Remote identifier 60 x 23 x 22mm Weight Cable Tester 215g Remote identifier 35g IV SETUP SELECTIONS The setup mode allows to select and calibrate cable characteristics Once changed these settings are stored and remain in the tester even when tester is turned off Setup items Select cable type UTP FTP or COAX Select a cable category Select a wire size...

Page 4: ...ey 3 Press keys until the desired category is displayed then press enter key 4 Press key until the desired wire size is displayed then press enter key 6 5 Press key to choose proceeding or not proceeding the function then press enter key 6 Press key until the desired is enable or disable then press enter key 7 Press SET key to exit this mode ...

Page 5: ... Key These cable parameters are stored and will remain in memory even if the test tool is turned off All future measurements for this cable type are compared to these new parameters until another cable is selected or another calibration is performed Note 1 Hidden calibrating cable length mode Press key to turn off the meter Press and hold down and keys then press key to turn on the meter until LCD...

Page 6: ... cable then a length measurement that is less than the known cable length would indicate a possible open in the cable The tester if a failure is detected additional information can be viewed with the keys The failure messages refer to individval wires rather than pairs of wires The TEST mode failure messages are described in following tables Test failures without remote unit FAILURE DISPLAY DESCRI...

Page 7: ...esired refer to CALIBRATING CABLE LENGTH described on this manual Before a length measurement is made the tester performs Test Cables described in this manual to prevent any cable failures from corrupting the length measurement Cable length measure procedure 1 Select cable type under test 2 Connect the cable and test to the appropriate connector on the tester 3 Press LENGTH key 4 Use or key to scr...

Page 8: ... enter the read memory data mode LCD shows R and memory location numbers additional information can be viewed with the key 3 Press key to scroll through the logged readings 4 Press MR key again to exit READ mode LCD will show Out r EAD 5 Erase the memory of dataloggeer Press key to turn off the meter Press and hold down MR key then press key to turn on the meter until LCD shows dEL press key to cy...

Reviews: