TEST

nF

ft

m

11

7

6

5

4

1

10

6

7

2

3

8

4

12

 LCD Display :

Custom large size LCD.  For more information, press ▼ ▲ key to 
display the additional information.

 

TEST key :

 Test the attached cable and indicate a pass or 

failure information base on the specified parameters for the 
selected cable.

 

  

Power key :

 On or Off.

 SET key :

 Access to cable selection, cable calibration, and 

other test tool settings.

 LENGTH measurement key :

 Measure the length of each 

pair of twisted pair cable or coaxial cables in meters or feet and 
tests for anomalies.

 WIREMAP test key :

 T0 display wiring connections, opens, 

shorts, and split pairs.

 ▼ ▲keys :

 Scroll through a selection of choices or multiple 

displays.

 

 ENTER key :

 Enter a selection into the test tool and move 

to the next setting selection.

 M (Memory), R (Read) key : 

Data memory and read 

( 99 sets ).

 RJ45 jack :

 Standard 8-pin modular jack for connecting UTP 

and FTP cable.

11

 Remote Identifiers #1 ~ #8.

12

 BNC connect for connecting coaxial cables.

III.

 SPECIFICATIONS

Cable Length Measurements
Range : 1.0 to 350m (2-999 ft)
Accuracy : 5% + 1m (5% +3ft)
Cables > 150 meters : 10% + 1m (10% + 3 ft)
Resolution : Measurement Unit in Feet : 
Cables < 100 ft : 0.5 ft ,  Cables > 100 ft :1ft
Measurement Unit in Meters.
Cables < 100 meter : 0.5m , Cables > 100 meters :1m
Failures Detected
SHORTS
Range of short detection : 0 to 350m ( 0 to 999ft)
Accuracy of distance to a short (Assumes short is 0

Ω

)

UTP/FTP : 7% + 3m (7% + 10ft)
Coaxial Cables : 10% + 10m (10% + 30ft)

Summary of Contents for 46

Page 1: ...t also tests up to 8 different cables at one end A stored cable library provides quick access to common cable types U S Pat No Des 446 135 The Cable Tester comes with One remote identifier 1 RID46 234 Optional for 2 3 4 RID46 5678 Optional for 5 6 7 8 One patch cable RJ 45 to RJ 45 30 cm long RJ45 RJ45 female coupler connector Instruction manual Carrying case 6 pcs AAA 1 5V Battery CAUTION The tes...

Page 2: ... split pairs keys Scroll through a selection of choices or multiple displays ENTER key Enter a selection into the test tool and move to the next setting selection M Memory R Read key Data memory and read 99 sets RJ45 jack Standard 8 pin modular jack for connecting UTP and FTP cable 11 Remote Identifiers 1 8 12 BNC connect for connecting coaxial cables III SPECIFICATIONS Cable Length Measurements R...

Page 3: ...60 70 RH Dimensions Cable Tester 150 x 72 x 35mm Remote identifier 60 x 23 x 22mm Weight Cable Tester 215g Remote identifier 35g IV SETUP SELECTIONS The setup mode allows to select and calibrate cable characteristics Once changed these settings are stored and remain in the tester even when tester is turned off Setup items Select cable type UTP FTP or COAX Select a cable category Select a wire size...

Page 4: ...ey 3 Press keys until the desired category is displayed then press enter key 4 Press key until the desired wire size is displayed then press enter key 6 5 Press key to choose proceeding or not proceeding the function then press enter key 6 Press key until the desired is enable or disable then press enter key 7 Press SET key to exit this mode ...

Page 5: ... Key These cable parameters are stored and will remain in memory even if the test tool is turned off All future measurements for this cable type are compared to these new parameters until another cable is selected or another calibration is performed Note 1 Hidden calibrating cable length mode Press key to turn off the meter Press and hold down and keys then press key to turn on the meter until LCD...

Page 6: ... cable then a length measurement that is less than the known cable length would indicate a possible open in the cable The tester if a failure is detected additional information can be viewed with the keys The failure messages refer to individval wires rather than pairs of wires The TEST mode failure messages are described in following tables Test failures without remote unit FAILURE DISPLAY DESCRI...

Page 7: ...esired refer to CALIBRATING CABLE LENGTH described on this manual Before a length measurement is made the tester performs Test Cables described in this manual to prevent any cable failures from corrupting the length measurement Cable length measure procedure 1 Select cable type under test 2 Connect the cable and test to the appropriate connector on the tester 3 Press LENGTH key 4 Use or key to scr...

Page 8: ... enter the read memory data mode LCD shows R and memory location numbers additional information can be viewed with the key 3 Press key to scroll through the logged readings 4 Press MR key again to exit READ mode LCD will show Out r EAD 5 Erase the memory of dataloggeer Press key to turn off the meter Press and hold down MR key then press key to turn on the meter until LCD shows dEL press key to cy...

Reviews: