background image

18 

Roto-Jet II

MaInTenanCe InsTRUCTIOns

Before Each Use

1.  Inspect your Roto-Jet II® for any obvious damage or missing parts.
2.  Check the power cord for cracks or wear.
3.  Test the GFI plug to insure proper functioning.
4.  Inspect the manifold o-ring. Replace if necessary.
5.  Make sure the filter washer is in place and clean.
6.  Inspect the foot switch air hose(s) for damage.
7.  Check the fuse, replace if necessary.
8.  Tighten all screws and bolts.
9.  Make sure all the vents cut in the machine casing are clear.
10. 

Briefly test run your Roto-Jet II®.
a.) If abnormal noise or vibration occur, turn the machine off immediately.
b.) See the “Trouble Shooting” section to diagnose the problem and correct the 

problem before further use.

After Each Use

1.  Disconnect the flexible shaft from the unit and drain the water from the casing.
2.  Spray a water displacement solution such as WD-40 into the casing from both ends, 

allowing the solution to run the entire length of the shaft.

3.  Coil the flexible shaft in a large diameter coil and tie it with the supplied Velcro strap.
4.  Disconnect the footswitch and safely store.
5.  Coil the power cord and tie together.

Long Term Storage

1.  Drain excess water from the flexible shaft casing.
2.  Generously spray a water displacement solution such as WD-40 into the casing from both 

ends, allowing the solution to run the entire length of the shaft.

3.  Store the flexible cable in large diameter coil and tie them with the supplied Velcro strap.
4.  To prevent freezing or other resultant damage, clear the manifold of water.

a.) Activate the solenoid by depressing the foot switch.
b.) Force compressed air through the garden hose fitting. The air will remove most of 

the water from the manifold.

5.  Disconnect the foot switch and safely store.
6.  Coil the power cord and tie together.
7.  Safely store the Roto-Jet II® and the accessory items for the next cleaning season.

Summary of Contents for Roto-Jet II 0650

Page 1: ...www elliott tool com Tube Pipe Cleaners Tube Testers Tube Plugs Tube Removal Tube Installation Roto Jet II 0650 0650R 110V 0750 0750R 220V Operating and Maintenance Instructions...

Page 2: ......

Page 3: ...troduction 4 Safety Guidelines 5 Grounding Instructions 6 Start Up 8 Operation Instructions 9 Parts List Diagrams 10 Maintenance Instructions 18 Troubleshooting 19 Flexshaft Repair 21 Technical Inform...

Page 4: ...se welcome to our company our products are our ambassadors If this is a repeat purchase you can rest assured that the same value you have received in the past will continue with all of your purchases...

Page 5: ...ssary Then make certain the cord is or equal rating or larger than the machine power cord Check power cords before using Damaged cords can reduce performance or cause a fatal electric shock Unplug the...

Page 6: ...NG Warning Improper connection of this equipment grounding conductor can result in a risk of electrocution Check with a qualified electrician or service technician if you are in doubt as to whether th...

Page 7: ...n Verify that the power light is on and the GFI is now operational 5 If the GFI fails to reset or fails to turn off when all appropriate buttons are pressed check to make sure that a You have fully de...

Page 8: ...is properly installed in the groove of the manifold Insert the drive coupling into the drive socket inside the manifold tighten the manifold cap onto the manifold Firm hand tightening will be sufficie...

Page 9: ...sing toward the machine Mark the casing at that point using electrical tape or a hose clamp snugly tightened on the casing This is to prevent the cleaning tool from exiting the tube NOTE Allowing the...

Page 10: ...Barbed Elbow 06550041 1 13 Solenoid Valve 110V 06511028 1 14 Nipple Connector 06540032 1 15 Manifold with Drive Shaft 06519175 1 16 Motor Coupling 06515011 1 17 Air Switch 06518120 1 18 Cable Speed C...

Page 11: ...ed Elbow 06550041 1 13 Solenoid Valve 220V 07511028 1 14 Nipple Connector 06540032 1 15 Manifold with Drive Shaft 06519175 1 16 Motor Coupling 06515011 1 17 Air Switch 06518120 1 18 Cable Speed Contro...

Page 12: ...2 Barbed Elbow 06550041 1 13 Solenoid Valve 110V 06511028 1 14 Nipple Connector 06540032 1 15 Manifold with Drive Shaft 06519175 1 16 Motor Coupling 06515011 1 17 Reversing Air Switch 06518131 2 18 Ca...

Page 13: ...bed Elbow 06550041 1 13 Solenoid Valve 220V 07511028 1 14 Nipple Connector 06540032 1 15 Manifold with Drive Shaft 06519175 1 16 Motor Coupling 06515011 1 17 Reversing Air Switch 06518131 2 18 Cable S...

Page 14: ...14 Roto Jet II PARTS LISTS DIAGRAMS 0650 and 0750 Parts Diagram...

Page 15: ...Roto Jet II 15 PARTS LISTS DIAGRAMS 0650R and 0750R Parts Diagram...

Page 16: ...0R Toggle Switch 10 amp Fuse Diaphram Switch Right Diaphram Switch Left Potentiometer Ground To Case Solenoid Common Normaly Open Common 115 A C Ground SIG 15V 15V TACH COM EN M1 M2 L1 L2 Motor 115v 2...

Page 17: ...0750R Toggle Switch 10 amp Fuse Diaphram Switch Right Diaphram Switch Left Potentiometer Ground To Case Solenoid Common Normaly Open 230v 230v Ground SIG 15V 15V TACH COM EN M1 M2 L1 L2 Motor 115v 230...

Page 18: ...cement solution such as WD 40 into the casing from both ends allowing the solution to run the entire length of the shaft 3 Coil the flexible shaft in a large diameter coil and tie it with the supplied...

Page 19: ...d Machine makes unusual noise or vibrates when operated Check for loose or missing cover screws Remove cover and check for loose or missing motor mounting bolts Check the alignment of the motor drive...

Page 20: ...hine on the floor Flexible Shaft prematurely breaks at the tool end Flexible shaft is allowed to exit the far end of the tube while the shaft is still rotating Flexible shaft is being forced through a...

Page 21: ...the coupling NOTE When replacing the motor coupling insure that the washer has been placed onto the core before inserting the motor coupling 4 Locate the assembly of the core and coupling in the prop...

Page 22: ...s Fuse 10 Amp Shaft Speed 0 to 1800 RPM Adjustable Dimensions 22 L x 11 W x 10 H Weight 35 lbs Water Input Garden Hose 0750 0750R Motor 1 2 HP DC Motor Power Supply 220 Volt 50 60 Hz 6 Amps Fuse 10 Am...

Page 23: ...riginal manufacturer s warranty to Seller Seller shall not be liable for any damages or delays caused by defective material or workmanship No allowance will be made for repairs or alterations made by...

Page 24: ...24 Roto Jet II...

Page 25: ......

Page 26: ...800 332 0447 Fax 1 937 253 9189 www elliott tool com Printed in the USA 06 2017 Elliott Tool Technologies Ltd TM 46 PL 18 Elliott Tool offers a complete line of precision tube tools to meet your needs...

Reviews: