background image

Installation Instructions  

 

 

11 of 12

Identifying proper mounting location: It will be helpful to determine whether your Gel-coat 

or Acrylic reinforced shower unit model has a small molded ridge or “water runoff assist” or 

trench design on your unit. You will find this feature on the floor of approximately 1-3 inches 

from the front entry edge of your shower unit.  The inside edge of the water retainer should 

rest on the crown of the ridge allowing the water to run off properly.  Use this ridge as your 

guide to mounting the retainer parallel with the water run off ridge.
Models less the ridge: All name brand barrier free showers that may not have a water run 

off ridge or recessed trench and applications such as tile, marble or cement floor surfaces, 

purchaser must determine the proper mounting location and length. Helpful hint: determine 

by desired location of curtain or directly below curtain rod.

Tools & Materials required: Utility Knife, Tape measure, Straight edge, Clear or White 100% 

Silicone Adhesive caulk, Blue Masking tape, Rubbing Alcohol, bucket of water and clean 

rags. 

INSTALLATION STEPS WITH FINISHED END CAPS

1. Thoroughly clean threshold surface of all soap scum and debris using standard bath 

cleanser.  Chemically clean surface with rubbing alcohol.
2. Verify the required length anticipating the vertical rise, making certain there is enough 

retainer strip to make a vertical rise on the end walls.
3. Determine and mark center point of shower.
4. Determine and mark center point of water retainer strip. 
5. Turn over water retainer strip and make cut on orange peel off strip at half way mark.  

Peel off a portion (approx. 4") of the orange peel off strip in one direction exposing the 

adhesive.
6. Align strip with pre-determined pencil mark or molded ridge crown of shower unit starting 

at the half way mark.  Press on and adhere approximately 4" of strip.  Pull and stretch to wall 

and align before removing remainder of orange peel off strip.  Press into place.
7. Peel, stretch, alien and pull remaining half to wall.  Press into place.
8. Push in the male end of your end cap into the water retainer.  Adhere end cap to unit 

with adhesive caulk and wipe clean. White or clear adhesive type caulk is recommended.
9. Use masking tape to temporarily hold cap in place until adhesive cures.
10. Optional: The outer edges beneath the retainer may be caulked if desired to prevent 

soap and shower debris from lodging beneath the retainer. The adhesive tape does not 

extend to the edge (by design) to allow the retainer to absorb the impact energy of a 

rolling shower chair in high use applications.  Wipe off excess caulk and let cure (according 

to caulk specifications) prior to shower use.

www.ellasbubbles.com 

Page 15 11/13

Summary of Contents for 3838 BF 4P.5

Page 1: ...75 Center 6030 BF 5P 1 0 Right Left 6036 BF 5P 875 Center 5430 BF 4P 1 0 Right Left 6033 BF 5P 1 0 Right Left 6036 BF 5P 1 0 Right Left Representing these Barrier Free Roll in Shower model numbers 604...

Page 2: ......

Page 3: ...tarted Tools and Materials 1 Planning your Installation 2 3 Framing Diagrams 4 Installation Instructions 5 16 Collapsible Dam Instructions 17 19 Warranty Information 20 Warranty Activation Form 21 22...

Page 4: ......

Page 5: ...0 1 1 4 wood screws solid wood flooring adhesive 2 one gallon buckets per shower or 100 silicone adhesive 2 gallons of water for mixing bedding compound and water test around drain tube of white bathr...

Page 6: ...an the size of the shower This product is manufactured to tight specifications The 1 4 over sizing is for maneuvering and installation ease If 1 4 over is not reasonable sizing closer to the product a...

Page 7: ...installing on the one piece back wall or side wall Plan for routing the water supply lines to the control valve installation location 5 In the installation location the drain opening in the floor shou...

Page 8: ...6036 L R 6060 6048 6036 C 6238 6232 A B C D 38 7 8 48 1 4 60 1 4 60 1 4 60 1 4 60 1 4 60 1 4 60 1 4 60 1 4 60 1 4 62 5 8 62 5 8 62 5 8 38 1 2 19 3 8 31 5 16 32 1 2 16 3 8 30 1 8 61 1 4 30 1 8 30 1 8 4...

Page 9: ...e silicone floor adhesive and minimal screws to secure to the framework Installation Instructions 1 of 12 6 Carefully measure the framing pocket to assure it is of proper size for the unit to be insta...

Page 10: ...f cardboard in the floor of the shower to protect the floor during the additional steps of installation There is a cut out for this on the pan box Installation Instructions 2 of 12 9 Once the shower p...

Page 11: ...sition to the back framing Use a piece of scrap 2 x 4 lumber to temporarily secure it See the example in Figure 12 Installation Instructions 3 of 12 12 The next step is to permanently install the show...

Page 12: ...entire installation process though step 23 must continue If for any reason the installation cannot be completed within the working time of the adhesive after step 16 jump ahead to step 23 Non shrink...

Page 13: ...te the valve installation and connection to hot and cold water supply at this time Also complete shower supply connection Strap pipes to framing if required This is the last access to the plumbing bef...

Page 14: ...larger than 1 8 will be present where the side walls mate the back wall Use wood shims or furring strips to fill any space between the back wall flange and the studs Align the wall section where it me...

Page 15: ...ts on the bottom of the wall Clear your fingers and slide the wall panel toward the back wall Make sure the alignment pins in the back wall index into the holes on the side wall See Figure 24 When sea...

Page 16: ...h opening no larger than 1 8 Figure 27 Installation Instructions 8 of 12 11 24 Now that all wall panels are installed remove the protective cardboard from the floor and use a 2 foot level to re check...

Page 17: ...and securely tighten each of the six 6 screws THIS COMPLETES THE INSTALLATION OF THE SEAT INSTALLATION INSTRUCTIONS FOR GRAB BARS Recommended tools for installation 1 4 Power Drill 1 8 drill bit when...

Page 18: ...manufactured units are designed with a radius where the floor transitions or meets the wall This is to ensure proper structural strength where the wall meets the floor The installation of end caps is...

Page 19: ...alcohol 2 Verify the required length anticipating the vertical rise making certain there is enough retainer strip to make a vertical rise on the end walls 3 Determine and mark center point of shower...

Page 20: ...ace 9 Before removing remainder of orange peel off strip stretch retainer to opposite wall mark and template for proper location proceeding final cut 10 Remove remaining orange peel off strip and stre...

Page 21: ...tifying proper mounting location It will be helpful to determine whether your fiberglass reinforced shower unit has a small molded ridge or water runoff assist design on your unit You will find this f...

Page 22: ...le today ORDER THE CORRECT LENGTH Make sure you have ordered the correct length See chart below The water retainer strip is designed to travel along the floor to the wall radius until vertical then ca...

Page 23: ...17 Tile Application Grout Line joints The grout joints or entire outer edge beneath the retainer must be caulked to prevent soap and shower debris from lodging beneath the retainer The adhesive tape...

Page 24: ......

Page 25: ...carry a thirty 30 year limited warranty against manufacturing defects This warranty shall be voided if the unit is moved from its place of initial installation or is not installed in accordance with t...

Page 26: ......

Page 27: ...tions test by using a 2 food level from the drain to all adjacent walls All cure times for bonding sealing agents have been properly observed and the customer has been clearly notified and instructed...

Page 28: ...taller s Name _______________________________________________ Address City State ZIP ____________________________ ________________________________ Telephone E mail ___________________________ ________...