background image

DS80IR5D-001A 

 

Enable the control unit to run the device learning procedure. Refer to the control unit instruction manual for details. 

 

Hold the Test button on the front cover pressed. 

 

Refer to the instruction manual of the control unit to complete the learning process. 

 

After having integrated the detector, set the control unit to “

Walk Test

” mode: keep the detector in the required position 

and press the Test button to confirm that the concerned position is within the communication range of the control unit; 

see the instruction manual of the control unit to complete the learning procedure. 

 

Proceed with the installation after having ascertained that the detector is working in the desired position. 

Mounting method 

The detector was designed to be mounted on a flat surface or in a corner using the fixing screws and the anchor bolts provided. The 
hole arrangements are provided on the base where the plastic is thinner and may be broken for mounting. The two hole arrangements 

are used to fix on a surface, while the four hole arrangements are used for fixing in a corner, as shown in the following figure. 

 
Surface mounting 

I. 

Remove the fixing screws and the cover. 

II.  Perforate the appropriate hole arrangements on the inner side of the base. 
III.  Using the template for the holes, make the holes in the surface. 
IV.  Insert the anchor bolts if the device is fixed to plaster or bricks. 
V.  Screw the base into the anchor bolts. 
VI.  Screw the cover onto the base. 

Corner mounting: 

I. 

Perforate the four arrangements for corner holes. 

II.  Using the holes as a template, make the holes on the surface. 
III.  Insert the anchor bolts.  
IV.  Screw the base into the anchor bolt. 
V.  Screw the cover onto the base. 

Installation 

 

Choose the position of the detector, i.e. either in a corner or on a surface. 

 

After having selected the installation position, follow the procedure described above to mount the detector. 

 

Press the Test button to enter Test mode. Move in the protected area and observe when the LED lights up to check that 

the detection coverage is adequate. 

 

Installation is complete when the detection coverage is appropriate. 

 

Installation advice 

The detector was designed to operate on a range of 12 meters if mounted at a height of 1.9 metres and with an area in which small 
animals will not be detected (Pet Immunity function) which reaches up to 7 m.  
If installed higher, the Pet Immunity range can be extended but, in this case, carefully check the blind area in which there will be no 

detection because an intruder in this area could go undetected. 

It is advised to install the detector in the following positions:

 

 

Mount the detector at a height of 1.9-2.0 metres to optimise performance: 

 

Select a position in which an intruder would normally cross the field of vision of the detector from one side to the other. 

 

Mount it in a corner to have the widest view possible. 

 

Mount it where the field of vision is not obstructed, e.g. by curtains, ornaments etc. 

Restrictions 

 

Do not position the detector directly facing a door protected by the door contact because the wireless signals of the door contact 
and of the detector could be transmitted in input at the same time, causing the signals to cancel each other out. 

 

Do not install the detector fully exposed to direct sunlight. 

 

Do not install the detector in areas in which devices which could cause sudden changes of temperature in the detection area 
are present, such as air conditioning units, radiators etc. 

 

Avoid large size obstacles in the detection area. 

 

Do not point directly towards source of heat, such as fires or boilers, and do not install over radiators. 

 

Avoid moving objects in the detection area, i.e. curtains, soft furnishings etc.  

 

 

Hole arrangements for 

corner fixing x 4 

Hole arrangements for 
fixing on surface x 2 
(visible internally) 

Summary of Contents for IRP600

Page 1: ...ity function Detecteur infrarouge avec immunite aux animaux domestiques Infrarot melder Pet Immunity Manuale d uso installazione e programmazione Installation programming and functions manual Notice di installation programmation et utilization Installations programmier und gebrauchsanleitun I EN FR DE ...

Page 2: ... non riceve segnali di supervisione trasmessi da un certo rivelatore per un tempo predeterminato viene generato un allarme di Supervisione Funzione Sensitivity Increaser Aumento di sensibilità È possibile utilizzare la funzione di incremento della sensibilità per aumentare la sensibilità di rilevamento Per aumentare la sensibilità di rilevamento inserire il jumper JP3 posizione ON Per mantenere la...

Page 3: ...II Usando la base come dima praticare i fori sulla superficie IV Inserire i tasselli se si esegue il fissaggio su intonaco o mattoni V Avvitare la base nei tasselli VI Avvitare il coperchio sulla base Montaggio ad angolo I Perforare le quattro predisposizioni per i fori angolari II Usando i fori come dima praticare i fori sulla superficie dell angolo III Inserire i tasselli IV Avvitare la base nel...

Page 4: ... area di rilevamento ovvero tende tappezzerie ecc Specifiche tecniche Alimentazione 1 batteria CR123A 3V Autonomia batterie 5 anni valore tipico può variare in base all uso Frequenza radio bidirezionale 868 MHz Portata infrarosso max 12 m con angolo di 110 Portata PET Immunity 7 m con angolo di 110 e altezza di installazione di 1 9 m dal suolo Temperatura operativa 10 C 45 C Dimensioni 53 2mm X 67...

Page 5: ...transmitted by a given detector for a predetermined time Sensitivity Increaser function This function can be used to increase detection sensitivity To increase detection sensitivity connect the Jumper JP3 or use position ON Use position OFF to maintain normal sensitivity Test mode The detector can be set to Test mode by pressing the Test button on the front cover for a few seconds In Test mode the...

Page 6: ...aving selected the installation position follow the procedure described above to mount the detector Press the Test button to enter Test mode Move in the protected area and observe when the LED lights up to check that the detection coverage is adequate Installation is complete when the detection coverage is appropriate Installation advice The detector was designed to operate on a range of 12 meters...

Page 7: ...7mm X 89 2mm Weight 100g Compliant under EN 50131 Grade 2 ClassⅡ SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby URMET S p A declares that the radio equipment type INFRARED DETECTOR WITH PET IMMUNITY FUNCTION IRP600 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www elkron com ELKRON Tel 39 011 3986711 Fax ...

Page 8: ...réalise régulièrement des autodiagnostics transmettant un signal de supervision à intervalles réguliers Si l unité de contrôle ne reçoit pas de signaux de supervision transmis par un certain détecteur dans un temps déterminé elle active une alarme de supervision Fonction Sensitivity Increaser Augmentation de sensibilité Utiliser la fonction d augmentation de la sensibilité pour augmenter la sensib...

Page 9: ...tué dans du plâtre ou des briques Visser la face arrière dans les chevilles Visser le couvercle sur la face arrière Montage en angle Percez les repères de fixation prédécoupés pour les trous angulaires Utiliser un gabarit pour percer les trous sur la surface de l angle Insérer les chevilles Visser la base dans la cheville Visser le couvercle sur la base Installation Choisir l emplacement du détect...

Page 10: ...ne de détection rideaux décorations murales etc Caractéristiques techniques Alimentation 1 batterie CR123A 3V Autonomie pile 5 ans valeur typique qui peut changer en fonction de l utilisation Fréquence radio bidirectionnelle 868 MHz Couverture infrarouge 12 m max avec angle 110 Couverture PET Immunity 7 m avec un angle de 110 et une hauteur d installation de 1 9 m au dessus du sol Température de f...

Page 11: ... Detektor in der normalen Betriebsart führt er regelmäßig einen Eigendiagnose Test durch und überträgt in regelmäßigen Abständen ein Überwachungssignal Erhält das Steuergerät über einen bestimmten Zeitraum keine von einem bestimmten Detektor übertragene Überwachungssignale wird ein Überwachungsalarm generiert Sensitivity Increaser Funktion Empfindlichkeitssteigerung Die Funktion der Empfindlichkei...

Page 12: ...Winkelbefestigung dienen wie in der Abbildung dargestellt Montage auf Oberflächen I Die Befestigungsschrauben und die Abdeckung entfernen II Die jeweiligen für die Bohrungen ausgelegten Bereiche auf der Innenseite der Basis durchbrechen III Unter Verwendung der Bohrschablone die Bohrungen an der Oberfläche anbringen IV Die Dübel einsetzen wenn die Befestigung auf Verputz oder Ziegel erfolgt V Die ...

Page 13: ...ngen vorhanden sind die wiederholte Temperaturschwankungen im Erfassungsbereich verursachen können bzw Klimaanlagen Heizkörper usw Große Hindernisse im Erfassungsbereich vermeiden Nicht direkt auf Wärmequellen wie Herde oder Heizkessel richten und nicht über Heizkörpern installieren Vermeiden dass sich bewegliche Gegenstände im Erfassungsbereich befinden wie Vorhänge Wandbehänge usw Technische Dat...

Page 14: ...1A ELKRON Tel 39 011 3986711 Fax 39 011 3986703 www elkron com mail to info elkron it ELKRON ist ein eingetragenes Warenzeichen von URMET S p A Via Bologna 188 C 10154 Torino TO Italy HUwww urmet comUH MADE IN TAIWAN ...

Reviews: