35/52
HPA800
EXAMPLE 3
SIREN
inputs balanced (B4 OFF),
referred to positive (default)
CONTROL PANEL
relay1 programmed
for Intrusion or Intrusion/Manipulation.
Output U2 programmed OR or AND TC.
EXAMPLE 4
SIREN
inputs not balanced (default),
referred to negative (A1 OFF)
CONTROL PANEL
relay programmed
for Intrusion
Output TC referred to -V
R balancing ALL and TC inputs
10Kohm (not supplied)
R balancing SAB
in accordance with the
value of the balancing resistance
expected for the SAB input of the control
panel (15Kohm for ELKRON MP500
control panels)
R balancing SAB
in accordance with the
value of the balancing resistance
expected for the SAB input of the control
panel (2,7Kohm for URMET 1067 control
panels)
CONTROL PANEL
CONTROL PANEL
Summary of Contents for HPA800
Page 50: ...50 52 HPA800 ...