30/52
HPA800
3.1 INITIAL DIAGNOSTICS
The HPA800 siren is equipped with innovative diagnostic functions to allow the installer to check correct
operation and connection of the siren to the control panel before closing the siren cover and completing
installation.
When the siren is powered, by connecting the battery or the voltage from the control panel, a sequence of low
volume tones is emitted and all LED simultaneously flash in order to check the correct operation of horn and
LEDs.
Then, the siren emits a LED flashing and tone cycles to indicate the condition of the inputs, as shown in the
following table:
* only if option GRI/HPA800 is present
DIP
Function
OFF
ON
1
Alarm input
(ALL) polarity and
system status (TC)
referred to negative
referred to
positive
(default)
2
LED functions
system status
after switching on the
system, the state LED
flashes until the next
switch-off
The system status LED
is off
(default)
3
Select
sound type
sound “B”
sawtooth
sound “A”
sinusoidal
(default)
4
Siren
timer
8 minutes
4 minutes
(default)
DIP
Function
OFF
ON
1
Alarm memory
and fault indication
signalling
on
signalling
off
(default)
2
Logical input
system status (TC)
positive/negative drop =
system off
positive/negative drop =
system on
(default)
3
Service
tones
enabled
disabled
(default)
4
Balance
alarm input (ALL)
and system status (TC)
the alarm inputs (ALL)
and the system status
(TC) were balanced by
means of 10 Kohm
resistor connected in
series
the alarm inputs (ALL)
and the system status
(TC)
are not balanced
(default)
On 4 central LEDs
(low brightness)
On horn
(low volume)
Siren condition
3-flash cycles
-
at least either the alarm input, the cover
microswitch or the anti-foam protection* is open
2-flash cycles
-
cover microswitch and anti-foam protection* are at
rest but the alarm input is open
3-flash cycles
cycles of 3 tones
the alarm input is at rest but at least either the cover
microswitch or the anti-foam protection is open