25/44
HPA700M
3.0 SIREN MODULE
TAMPER-type connector for connection of the anti-
opening/anti-removal microswitch
AP connector for speaker connection
DEMO jumper for listening to the 8 siren sound
modes and/or checking the fault codes
+B
Positive battery (connected at the factory)
-B
Negative battery (connected at the factory)
+
Supply positive
-
Supply negative
AL
Alarm input. Programmable NC or double balanced (6K8
– 5%) referred to positive or negative
S
System status input. Programmable NC or double balanced (6K8
– 5%) referred to positive or negative.
To ensure compliance with the standard, it should be closed to the chosen reference.
TA
TAMPER contact output terminal (normally closed)
TA
F
Failure output: it supplies a positive which, however, is lost in the event of a failure
D
Data line for the protection module (if present)
+P
Positive available for protecting module supply (if present)
Drilled riser
for securing
internal cage
Drilled risers
for securing
internal cage
Drilled riser
for securing
external
cover
Wall
fastening
hole
Wall
fastening
hole
Wall
fastening
hole
Cables
passage
piercing
arrangem.
Battery
housing
Pre-setting for
protection module