(((ELKRON))) - CT10-M / CT11-M
18
6.8 DEFAULT SETTINGS
Input status
IN1 = normally closed, subjected to TC, instantaneous
IN2 = normally closed, subjected to TC, instantaneous
IN3 (TC) = normally closed
Output status
U3 = deactivating, switchable, maintained
U4 = deactivating, switchable, maintained
U5 = deactivating, switchable, maintained
Input/telephone number/message type association
IN1 =
1st 2nd 3rd 4th ..VOICE MESSAGE
5th ...................TEXT MESSAGE
6th ...................VOICE AND TEXT MESSAGE
IN2 =
7th 8th 9th 10th VOICE MESSAGE
11th ................. TEXT MESSAGE
12th ................. VOICE AND TEXT MESSAGE
Failure/telephone number/message type association
Failure = 6th ...................VOICE AND TEXT MESSAGE
Telephone number/network association
(CT11-M only)
Tel. 1 - 12 = GSM channel message
Network enable
(CT11-M only)
Enabled GSM and PSTN networks
PSTN parameters
(CT11-M only)
Country: Italy
Dialling method: MF
PBX derivation: off
Tone check: off
Answer check: off
PSTN line test: off
Answering service (for remote controls)
Off
User code
Code 111111
Engineer code
Code 333333 (enabled)
RESETTING DEFAULT PARAMETERS
To return the communicator to default parameters
:
1. Disconnect power (and battery, where present).
2. Reconnect power. The buzzer will beep.
3. While the buzzer is beeping, press
and
3
DEF
at the same time. Wait for the
buzzer to sound continuously and start beeping faster. The message
DEFAULT PARAM-
ETERS
will appear on the display when the procedure is over.
This procedure will delete the telephone numbers and the text messages but
not the programmed voice messages.