![Elkron CT10-M Installation Manual Download Page 36](http://html.mh-extra.com/html/elkron/ct10-m/ct10-m_installation-manual_2393475036.webp)
(((ELKRON))) - CT10-M / CT11-M
36
8.13 INPUT PROGRAMMING MENU
• This function is used to program the status of the two alarm inputs and the communicator
TC input.
• Each input can be programmed as normally closed, balanced closed or normally open.
The alarm can either be subjected according to the status of input 3 (AND TC) or kept
active at all times (24H/24H).
• An input is subjected to the status of input 3 (AND TC) and can be programmed with a
delay of 5 sec, 15sec. etc
to confirm
selection
to confirm
selection
to confirm
selection
Select AND TC programming to
select the required delay (5s,
15s, 30s, 60s, 90s or instan-
taneous).
to confirm
selection
to select the inputs
to select the inputs
ENGINEER MENU
INPUT PROGR,
INPUT PROGR,
INPUT NR: 1
INPUT PROGR,
INPUT NR: 2
INPUT : 1
normALLY CLOSED INPUT : 1
N.C. TERMINATED
INPUT : 1
normALLY OPEN
INPUT : 1
24hR TYPE
INPUT : 1
NOT USED
INPUT : 1
and WITH tc
INPUT : 1
INSTANTANEOUS
INPUT : 1
5 S DELAY
INPUT: 1
90 S DELAY