background image

- 17 -

^

^

^

^

^

^

°C

°C

E
N

FL-H

 - setting the 

max. temperature for 
underfl oor heating ***

FL-L

 - setting the 

minimum fl oor 
temperature ****

Corr

 - correction of 

time deviation, sets the 
number of seconds for 
10 days, range ± 99

***  

oFF

 - fl oor temperature function is switched off , the actuator(s) of the type RFSA-6x is(are) controlled.

Range 20 - 35 °C, fl oor temperature function is switched on, the actuator(s) of the type RFSTI-11B is(are) controlled (with 
date of manufacture from 03/2013).

**** Used for tempering the fl oor when using a diff erent heating source.

oFF

 - the function for maintaining the minimum fl oor temperature is switched off .

Range 20 °C up to the max. set fl oor temperature (

FL-H

).

Summary of Contents for RFTC-50/G

Page 1: ...RFTC 50 G C E N Wireless temperature controller ...

Page 2: ...echnical parameters Battery replacement Description of device Description of display Description of control Selecting the heating mode Setting the temperature for manual mode Entering the programming menu Entering the settings menu Example of programming the RFTC 50 G ...

Page 3: ...l wires connected parts or terminals are de energized While mounting and servicing observe safety regulations norms directives and professional and export regulations for working with electrical devices Do not touch parts of the device that are energized life threat Due to transmissivity of RF signal observe correct location of RF components in a building where the installation is taking place RF ...

Page 4: ...heaters etc b the internal sensor scans the temperature and based on the set command weekly program it switches on the actuator RFSTI 11B which also scans the critical floor temperature this occurs to prevent damage when opening a window This solution is especially suitable for underfloor heating control is performed using buttons individual symbols temperature battery mode etc are displayed on a ...

Page 5: ...ting position Mounting Protection Electromagnetic radiation degree Dimensions Frame plastic Frame metal glass wood granite Weight Related standards 2 x 1 5V bat AAA up to 1 year depending on number of controlled actuators 2 buttons v 5 C LCD characters Yes active blue symbols 1x internal sensor 0 55 C 0 3 C of scale 866 MHz 868 MHz 916 MHz bidirectionally addressed message 20 mm up to 100 m 4 0 55...

Page 6: ...ature sensor Attention When you instal iNELS RF Control system you have to keep minimal distance 1 cm between each units Between the individual commands must be an interval of at least 1s Prior to first assembly remove the moldings in the frame and peel off the protective film from the display After inserting the batteries all features for controlling the display function illuminate for 2 seconds ...

Page 7: ... 7 C E N Day of the week Heating mode Current temperature Control button Current time Circuit status Control button Hidden button Description of device ...

Page 8: ...communication with a paired actuator s setting the time locking the menu item or program manual mode setting the temperature output switched on when selecting heating function output switched on when selecting cooling function displays in the case of low battery voltage vacation mode constantly illuminated connection with all actuators successful flashing connection successful only with certain ac...

Page 9: ...after setting and locking of the menu item or program Long button press 2 s refusal of changed value return to original value and locking of the menu item or program Short press of hidden button 2 s closingmenu afterclosingthemenucommunicationwithactuatorsisperformed the default display indicates the update of the actuator status e g upon actuator power failure Long press of hidden button 2 s upon...

Page 10: ... set in the menu ProG item ECO OFF thermostat switched off when selecting the function heating the thermostat regulates to a non freezing temperature set in the menu in the item OFF when selecting the function cooling the thermostat is switched off and is not performing any regulation At the default display press and hold the button In the upper row of the display the indicator rEG appears and the...

Page 11: ...temperature flashes By short presses of the buttons you will change the value by an increment of 0 5 C By pressing and holding the buttons you begin accelerated setting of the value Aftercompletingthesettings after5secondsitautomaticallyreturnstotheinitialdisplay therebyconfirmingthetemperature change It also assesses the current and required temperatures and communicates with the actuator s ...

Page 12: ...elections each day separately working day weekend each day the same ECO setting the reduced temperature regulation to this temperature is performed in the Auto mode outside the set time segments StA time of start of the program step range 12 00 a m 11 50 p m increment 10 minutes ...

Page 13: ...rature in the program step range from temperature ECO to 40 0 C step 0 5 C The programming step number is indicated on the lower bar graph by the number of displayed lines 1 6 The day of the week for which the given program step is set is displayed in the upper corner of the display If the program type working day weekend is selected then for working days the symbols 1 2 3 4 5 are displayed and fo...

Page 14: ...or range 5 0 to 5 0 C step 0 1 C rF A the number of controlled actuators of the type RFSA 6x or RFSTI 11B range 1 4 1 2 3 4 according to the number of controlled actuators there are available 1 4 of the following items where the RF address of individual actuators is set ...

Page 15: ...0 2 to 5 0 C step 0 2 C bLt intensity of display back lighting OFF 1 10 For format the time display 12 24 FCE selection of function heating cooling HEAt CooL on the upper row the function is selected HEAt CooL and on the lower row there is the name of the menu item FCE ...

Page 16: ... local time time zone against UTC range 1 to 2 covers the countries in the EU For EU countries it is valid that the time shift always occurs at 1 00 UTC it is thus necessary to know the time zone to find out at what time in local time the winter and summer daylight savings time shifts are to occur In the upper row the period of vacation timer is shown in hours or days and the lower row indicates t...

Page 17: ...tion is switched off the actuator s of the type RFSA 6x is are controlled Range 20 35 C floor temperature function is switched on the actuator s of the type RFSTI 11B is are controlled with date of manufacture from 03 2013 Used for tempering the floor when using a different heating source oFF the function for maintaining the minimum floor temperature is switched off Range 20 C up to the max set fl...

Page 18: ... 18 C C C 0 6 12 18 24 Example of programming the RFTC 50 G Example of settings for actuator RFSA 6x RFSC 61 RFUS 61 and RFSTI 11B ...

Page 19: ...time switched off non freezing temperature set to 7 C maximum floor temperature 28 C minimum floor temperature 21 C time correction 0 Example of settings for 1 actuator type RFSA 6x with RF address 001234 with hysteresis of 0 6 C heating function time format 24 hr daylight savings time shit switched off non freezing temperature set to 7 C time correction 0 ...

Page 20: ...4863 02 98 2016 Rev 3 ELKO EP s r o Palackého 493 769 01 Holešov Všetuly Czech Republic tel 420 573 514 211 fax 420 573 514 227 elko elkoep com www elkoep com ...

Reviews: