background image

02-58/2016 Rev.8

RFSA-61M, RFSA-66M

Wireless switch unit

EN

Made in Czech Republic

1

2

3

1 x

PROG

1s

1 x

PROG

1s

1 x

2 x

Function switch on /

Description of switch on /

The output contact will be closed by pressing the button. 

Programming /

Press of programming button 

on receiver RFSA-61M (66M) 

for 1 second will activate re

-

ceiver  RFSA-61M  (66M)  into 

programming mode. LED is 

flashing in 1s interval. 

Two presses of your selected 

button on the RF transmitter 

assigns the function switch on 

(must be a lapse of 1s between 

individual presses).

Press of programming button 

on receiver RFSA-61M (66M) 

shorter then 1 second will fin-

ish programming mode. The 

LED lights up according to the 

pre-set memory function.

2

3

1 x

1

PROG

1s

1 x

PROG

1s

1 x

3 x

Function switch off /

Description of switch off /

The output contact will be opened by pressing the button. 

Programming /

Press of programming button 

on receiver RFSA-61M (66M) 

for 1 second will activate re

-

ceiver  RFSA-61M  (66M)  into 

programming mode. LED is 

flashing in 1s interval. 

Three presses of your selected 

button on the RF transmitter 

assigns the function switch off 

(must be a lapse of 1s between 

individual presses).

Press of programming button 

on receiver RFSA-61M (66M) 

shorter then 1 second will fin-

ish programming mode. The 

LED lights up according to the 

pre-set memory function.

2

3

1 x

1

PROG

1s

1 x

PROG

1s

1 x

4 x

Function impulse relay /

Description of impulse relay /

The output contact will be switched to the opposite position by each press of 

the button. If the contact was closed, it will be opened and vice versa.

Programming /

Press of programming button 

on receiver RFSA-61M (66M) 

for 1 second will activate re

-

ceiver  RFSA-61M  (66M)  into 

programming mode. LED is 

flashing in 1s interval. 

Four presses of your selected 

button on the RF transmitter as-

signs the function impulse relay 

(must be a lapse of 1s between 

individual presses).

 

Press of programming button 

on receiver RFSA-61M (66M) 

shorter then 1 second will fin-

ish programming mode. The 

LED lights up according to the 

pre-set memory function.

3/

7

U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected] 

U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected] 

 

EN

 Support: +381 63 479 880 | 

RS

Tehnička podrška +381 63 479 880 

 www.elkoep.rs

Jednokanalna prekidačka jedinica

RS

Funkcija uključivanja

Opis funkcije uključivanja

Izlazni kontakt zatvara se pritiskom na taster.

Programiranje

Pritiskom na taster za pro-

gramiranje na RF elementu 

RFSA-61M (66M) tokom 1 s 

element se prebacuje u re-

žim programiranja. LED lam

-

pica trepće u intervalima od 

1 sekunde.

Pritiskom  2x  na  taster  po  va

-

šem  izboru  na  RF  kontroleru 

dodeljuje se funkcija ( između 

svakog  pritiska  tastera  mora 

biti razmak od 1s).

Pritiskom na taster za pro-

gramiranje na RFSA-61M 

(66M)  kraćim  od  1  sekunde 

završava se režim programi

-

ranja.  LED  svetli  u  skladu  sa 

podešenom  funkcijom  me

-

morije.

Funkcija isključivanja

Opis funkcije isključivanja

Izlazni kontakt se otvara pritiskom na taster.

Programiranje 

Pritiskom na taster za pro-

gramiranje na RF elementu 

RFSA-61M (66M) tokom 1 s 

element se prebacuje u re-

žim programiranja. LED lam

-

pica trepće u intervalima od 

1 sekunde.

Pritiskom  3x  na  taster  po  va

-

šem  izboru  na  RF  kontroleru 

dodeljuje se funkcija ( između 

svakog  pritiska  tastera  mora 

biti razmak od 1s).

Pritiskom na taster za pro-

gramiranje na RFSA-61M 

(66M)  kraćim  od  1  sekunde 

završava se režim programi

-

ranja.  LED  svetli  u  skladu  sa 

podešenom  funkcijom  me

-

morije.

Opis funkcije impulsnog releja

Opis funkcije impulsnog releja

Izlazni kontakt se prebacuje u suprotno stanje svaki put kada se pritisne tas

-

ter. Ako je bio zatvoren - otvara se, ako je bio otvoren - zatvara se.

Programiranje

Pritiskom na taster za pro-

gramiranje na RF elementu 

RFSA-61M (66M) tokom 1 s 

element se prebacuje u re-

žim programiranja. LED lam

-

pica trepće u intervalima od 

1 sekunde.

Pritiskom  4x  na  taster  po  va

-

šem  izboru  na  RF  kontroleru 

dodeljuje se funkcija ( između 

svakog  pritiska  tastera  mora 

biti razmak od 1s).

Pritiskom na taster za pro-

gramiranje na RFSA-61M 

(66M)  kraćim  od  1  sekunde 

završava se režim programi

-

ranja.  LED  svetli  u  skladu  sa 

podešenom  funkcijom  me

-

morije.

Summary of Contents for iNELS RFSA-61M

Page 1: ...For more information see Installation manual iNELS RF Control http www elkoep com catalogs and brochures 1 7 U Energister d o o Noveških interniraca 1V 31000 Užice Serbia e mail office elkoep rs U Energister d o o Norveških interniraca 1V 31000 Užice Republika Srbija e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica ...

Page 2: ... the time delay between these commands must be a min of 1s press delay 1s release U Energister d o o Noveških interniraca 1V 31000 Užice Serbia e mail office elkoep rs U Energister d o o Norveških interniraca 1V 31000 Užice Republika Srbija e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica RS Indikacije ručna kontrol...

Page 3: ... set memory function 3 7 U Energister d o o Noveških interniraca 1V 31000 Užice Serbia e mail office elkoep rs U Energister d o o Norveških interniraca 1V 31000 Užice Republika Srbija e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica RS Funkcija uključivanja Opis funkcije uključivanja Izlazni kontakt zatvara se priti...

Page 4: ...Užice Serbia e mail office elkoep rs U Energister d o o Norveških interniraca 1V 31000 Užice Republika Srbija e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica RS Funkcija odloženog isključivanja Opis funkcije odloženog isključivanja Izlazni kontakt se zatvara otvara nakon pritiska na taster nakon isteka pode šenog v...

Page 5: ...tion does not affect the pre set memory function 5 7 U Energister d o o Noveških interniraca 1V 31000 Užice Serbia e mail office elkoep rs U Energister d o o Norveških interniraca 1V 31000 Užice Republika Srbija e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica RS Nakon isteka potrebnog vremena između 2 s 60 min reži...

Page 6: ...nkcije 1 4 koristi se za čuvanje poslednjeg stanja izlaza releja pre prekida napona napajanja promena izlaznog stanja se zapisuje u memoriju nakon 15 s od promene Za funkcije 5 6 ciljno stanje releja se odmah zapisuje u memoriju nakon vremena kašnje nja nakon ponovnog povezivanja napajanja relej se postavlja u ciljno stanje Isključena funkcija memorije Kada se napajanje ponovo poveže relej ostaje ...

Page 7: ...a e mail office elkoep rs EN Support 381 63 479 880 RS Tehnička podrška 381 63 479 880 www elkoep rs Jednokanalna prekidačka jedinica RS Upozorenje Uputstva za upotrebu su namenjena za ugradnju kao i za korisnike proizvoda Uputstva se uvek dobijaju uz proizvod Instalaciju i povezivanje smeju da obavljaju samo kvalifikovane osobe u skladu sa svim važećim propisima koja je detaljno upoznata sa ovim ...

Reviews: