Elkay Manufacturing Company 

  

(630) 574-8484 

 

 

2000000698 (Rev. A - 07/22)

ECP8_1J     ECP8_2J     ECP8_3J          

DESCRIPTION

1100000006

98778C

55996C

98773C

98777C

98776C

66703C

20282C

56237C

1

3

4

5

9

10

11

12

13

PART NO. 

ITEM 

NO.

 

115/220V - 50/60 Hz

*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL  

 ASSEMBLY.

 

NOTE:

 

All Correspondence Pertaining to any of the above water chillers or orders for repair parts must include model no.,  

 serial no. of chiller, name and part no. of replacement part.

DESCRIPTION

 2

*6

 7

 8

0000000244

0000000245

1000002147

1000002146

98751C

98752C

31506C

PART NO. 

Kit - Fan Mtr/Blade/Nut/ 

Shroud (50 Hz)

Kit - Fan Mtr/Blade/Nut/ 

W/O Shrd (60 Hz)

Comp Serv. Pak (50 Hz)

Comp. Serv. Pak (60 Hz) 

Kit - Elec/Relay/Cvr/Ol (50 Hz)

Kit - Elec/Relay/Cvr/Ol (60 Hz)

Power Cord (50/60 Hz)

ITEM 

NO.

 

220V 50/60HZ

kit - Evaporator Replace Assy

Kit - Heatx/Drier

Strainer

Kit - Cold Control/Screws

Kit - Compr Mtg/Grommets/Clips/Studs

Kit - Condenser/Drier

Drier

Bracket - Fan Mtg

Shroud-Fan

DESCRIPTION

 2

*6

 7

 8

98775C

36322C

0000000238

36208C

PART NO. 

Kit - Fan Motor/Blade//Nut/Shroud

Compressor Service Pack

Kit - Elect/Relay/Cover/Overload

Powercord

ITEM 

NO.

 

115V 60HZ

REPLACEMENT PARTS LIST

1

11

8

4

5

7

12

6

10

3

9

2

13

Fig. 3

Summary of Contents for ECP8

Page 1: ...ECP8_1J ECP8_2J ECP8_3J 630 574 8484 Elkay Manufacturing Company 2000000698 Rev A 07 22 Page 1 ECP8 Refrigeration Packages INSTALLATION CARE AND USE MANUAL...

Page 2: ...2 6 Warranty 5 3 Installation Preparation Read Before Beginning Installation 7 4 Tools and Supplies 7 4 1 Tools Required 7 4 2 Installer Supplied Parts 7 4 3 Tools Items required but not provided 7 5...

Page 3: ...y Alert Symbol and followed by a signal word such as WARNING or CAUTION 1 3 Definitions DANGER The signal word that indicates a hazard with a high level of risk which if not avoided will result in dea...

Page 4: ...rior to any maintenance make sure the unit is unplugged and circuit breakers are turned OFF Prior to installation test for live circuits or wiring inside the wall before cutting or drilling into the w...

Page 5: ...ust be installed properly by trained service person 2 2 Disclaimer The information contained in this Installation Use Care Manual is given free of charge It is based upon technical data which we belie...

Page 6: ...Page 6 Elkay Manufacturing Company 630 574 8484 2000000698 Rev A 07 22 ECP8_1J ECP8_2J ECP8_3J...

Page 7: ...risk of water damage Thoroughly flush all water lines and fittings of all foreign matter before connecting to chiller If inlet pressure is above 100 psig 0 69 MPa a pressure regulator must be installe...

Page 8: ...foreign matter before connecting to chiller If flushing does not remove all particles a water strainer should be installed in supply line This chiller is manufactured in such a manner that it does no...

Page 9: ...or cycling on the compressor overload protector 9 2 3 Waterflow Make sure that the water flow is proper If water flow is slow then inspect the filter or in line strainer for restriction Replace the fi...

Page 10: ...rt DESCRIPTION 2 6 7 8 0000000244 0000000245 1000002147 1000002146 98751C 98752C 31506C PART NO Kit Fan Mtr Blade Nut Shroud 50 Hz Kit Fan Mtr Blade Nut W O Shrd 60 Hz Comp Serv Pak 50 Hz Comp Serv Pa...

Reviews: