background image

12

DSWH160UVPC 

Installation and Maintenance Manual

2.  Cut, size and connect water and CO

2

 piping to fit your installation.

NOTICE: 

The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and 

51 psi (0.35 MPa) maximum. If the inlet water pressure is higher than 51 psi, the water pressure regulator 
supplied must be used.

NOTICE: 

An incoming flow rate of >1.0 gallon/minute is recommended for optimal quality of sparkling 

water.

NOTICE: 

Check all input piping and connections for leaks before connecting to the machine.

Water source: 

threaded 

fitting

Water 

source: 

open 3/8" 

pipe

Water filter

3/8"

 

 

quick 

connect 

adapter

3/8"

 

 

quick 

connect 

adapter

Water 

pressure 

regulator

Water 

piping cut 

to size

3/8” 

water 

tubing cut 

to size

Water piping 

cut to size

To water 

cooler

Short  

3/8"–

 

3/8" pipe

Using the quick connect fittings

To connect:

1.  Make clean, 90° cut to 

piping end.

2.  Push piping straight into 

fitting until it stops.

3.  Pull back to check that 

connection is secture.

To disconnect:

1.  Press in the end tab.
2.  Pull piping out.
3.  Release tab.

1/4” Gas tubing 

cut to size

Regulator

CO

2

 source

3/8” 90° quick 

connect elbow - 

Needed when unit 

is on a countertop

3/8” x 1/4” 

quick connect 

connector

1/4” tubing 

4” long

Recommended total 

lenght 6 feet

Use one of two 

connection 

methods

Summary of Contents for DSWH160UVPC

Page 1: ... Begin Requirements for Installation 7 Mounting Dimensions 7 Operating Environment 8 Water 8 Electrical 8 Tools You Will Need 9 Unpacking the Kit 9 What s in the Kit 10 Installing the Machine 11 Operating the Keypad 17 Routine Maintenance 18 Troubleshooting 21 Replacement Parts 24 NOTICE Read the instructions in this manual and retain for future reference Installation and Maintenance Manual ENERGY...

Page 2: ...6 95 EC O O the protection requirements of the Electromagnetic Compatibility Directive 2004 108 EC The electrical safety of the product is ensured only when it is properly connected to an efficient legally compliant grounding circuit UL standard for safety of drinking water coolers ANSI UL 399 Issued 2008 08 22 Ed 7 Rev 2013 10 18 CSA standard for refrigeration equipment CSA C22 2 No 120 Issued 20...

Page 3: ... taken to a dedicated recycling center for electrical and electronic equipment Immediately prior to scrapping cut off the power cable For more information on the treatment recovery and recycling of this product please contact the appropriate local office the waste disposal service or the reseller from which the product was purchased This product contains no CFCs or HFCs which contribute to global ...

Page 4: ...stainless steel O O Internal components made entirely of stainless steel O O High insulation ice bank ensures a high output of cold water still and sparkling O O Self diagnosis and alarm system responds to little or no water flow an accidental water leak or the need for CO2 cylinder replacement O O Energy Saving command when selected this feature enables standby functionality of the unit with cons...

Page 5: ...cover Front door Keypad Drip tray Water inlet CO2 inlet Front Panel lock LED alarms Energy Saving No low H2 0 CO2 pressure Cold sparkling dispenser Hot dispensers Energy Saving button Cold still dispenser DSWH160UVPC DSWH160UVPC Keypad ENERGY SAVING ENERGY SAVING Power cord ...

Page 6: ...65 1 Heater wattage 1000W Inlet water pipe ø 3 8 Power 110V 60Hz Power consumption 1350 W 11 A Working room temperature Min 41 F Max 107 6 F Min 5 C Max 42 C UNIT WEIGHT lb kg 71 65 32 5 SHIPPING WEIGHT lb kg 80 36 3 Dimensions W x D x H in mm 13 x 19 48 x 18 41 330 x 494 9 x 467 5 Dispensing area height in mm 10 67 271 Packaging dimensions W x D x H in mm 15 23 x 21 54 x 27 38 387 x 547 x 695 5 D...

Page 7: ...th 20 9 531mm Depth 23 2 589mm Height 22 4 569mm Height 28 711mm Height 12 75 324mm Depth 3 88 99mm Diameter 8 203mm Width 3 25 83mm Footprint 12 9 wide x 19 2 deep 330mm x 489mm Over counter includes 4 clearance on sides and back Under counter Water filter CO2 cylinder typical 20 pound DSWH160UVPC ...

Page 8: ...er main that supplies drinking water only O O Use of 3 8 diameter connections for DSWH160UVPC is recommended O O Turn off the main water inlet tap if the unit is not to be used for a long period Electrical O O Check that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site O O Do not use extension cables or multiple power sockets The machi...

Page 9: ...at they are not damaged Contact the carrier immediately if there has been any damage during shipping NOTICE Ensure that your machine is installed by a qualified technician in compliance with the manufacturer s instructions and the local safety guidelines NOTICE Only qualified technicians should access the internal components of your machine other than to fill the ice bank 2 8 adjustable wrenches 1...

Page 10: ...VPC water cooler 1 CO2 regulator 1 external water filter 2 3 8 quick connect connector 1 supply hose 1 2 ips x 3 8 tube x 12 long 1 3 8 x 3 8 90 quick connect elbow 1 water pressure regulator 1 10 coil CO2 tubing natural 1 4 OD 1 3 8 x 1 4 quick connect connector 1 4 piece of 1 4 OD tubing 1 10 coil water 3 8 OD tubing blue PLUS Front panel keys ...

Page 11: ... and CO2 cylinder 1 Use 2 Phillips head screws to mount bracket to under counter wall or DSCABWH cabinet panel 2 Use 4 Phillips head screws to mount filter head to bracket 3 Remove cap from filter Insert filter into filter head and turn clockwise right until it stops When installing external water filler within the DSCABWH cabinet please refer to the following mounting instructions 1 Use 3 Phillip...

Page 12: ...ater source threaded fitting Water source open 3 8 pipe Water filter 3 8 quick connect adapter 3 8 quick connect adapter Water pressure regulator Water piping cut to size 3 8 water tubing cut to size Water piping cut to size To water cooler Short 3 8 3 8 pipe Using the quick connect fittings To connect 1 Make clean 90 cut to piping end 2 Push piping straight into fitting until it stops 3 Pull back...

Page 13: ...rt piping from water supply directly into the ice bank inlet 4 Fill slowly until water starts to come out of the ice bank drainage pipe D 5 If you have to move the unit remember to empty the ice bank first 6 Turn off water supply and remove piping from ice bank inlet 4 Place the machine in its operating location NOTICE Ensure machine remains level while being lifted into place to prevent spillage ...

Page 14: ...rest socket 2 Open the front panel with the supplied key and press the power button at the top left of machine B NOTICE Chilling of the ice bank begins immediately when unit is turned on Complete chilling of ice bank will require around 30 minutes 1 hour The machine should not be used as a water dispenser until chilling is complete DSWH160UVPC DSWH160UVPC B B Water input CO2 input ...

Page 15: ...an be ignored during this step 8 Turn on the boiler NOTICE Never turn on the boiler unless you have filled the machine with water NOTICE Never turn on the boiler when the inlet water is disconnected 1 Open the front panel with the supplied key and press the boiler button at the top center of machine 2 After around 10 minutes the water reaches the setted temperature CAUTION Hot water reaches 185 F ...

Page 16: ...s purged of still water NOTICE If the No low CO2 error LED flashes during this step there is a problem with the connection to the CO2 source Check all components in the gas system before proceeding 11 Allow machine to complete initial chilldown NOTICE Complete chilling of ice bank will require around 30 minutes 1 hour The machine should not be used as a water dispenser until chilling is complete N...

Page 17: ...s on NOTICE Energy Saving mode slows down the activation time of the compression This mode should only be used when the machine will not be operated such as when the business has closed for the day To turn off Energy Saving mode Press the Energy Saving button or any of the dispensing buttons Alarms The blue LED on the left is flashing if an alarm is active O O Quick flashing Little or no water at ...

Page 18: ...etal fibers to clean the product Metal fibers have a tendency to disintegrate and release small metal particles that are embedded in the surface Metal particles oxidize and give the impression that the surface of the product is rusting Do not use abrasive cleaners or abrasive pads as these will scratch the surface of the product Do not use a water jet O O To remove limescale use a slightly acidic ...

Page 19: ...is operation must be carried out by your ELKAY reseller or by a qualified technician When required O O Replace the UV lamp CAUTION The light emitted by the ultra violet lamp may cause serious burns to the eyes and skin Disconnect the electrical source of supply of the UV radiation before opening the machine NOTICE The UV OUT lamp can not be installed on the hot water nozzle 1 Disconnect the unit f...

Page 20: ...hermostat 1 Set the thermostat between 5 and 6 to control the temperature of the cold water 2 If you want to avoid the formation of ice in the bank turn the thermostat screw located on the back side of the machine at least 1 4 anti clockwise COLDER OFF 1 2 3 4 5 6 7 ...

Page 21: ...CO2 cylinder is empty Replace the cylinder The pump is not working Force the pump to start Replace the pump if broken The solenoid is not working Repair or replace the solenoid The flow control valve is too tight Open the valve Problem Possible Cause Action To Take Water is not cold enough The ice bank is empty Fill the ice bank with water The thermostat is not adjusted properly Adjust the thermos...

Page 22: ...or connection at CO2 tank Replace seal The CO2 exit pressure lower than 36 psi 2 5 bar Set the pressure between 55 60 psi 3 5 4 bar A reset is needed Turn the machine off and back on Problem Possible Cause Action To Take Quick flashing blue LED no water alarm on The pump runs for 4 minutes continuously Check why the water is not entering the unit and fix it The water valve is closed Open the valve...

Page 23: ...23 1000003740 Rev A 02 2017 Contacting Customer Support Elkay Manufacturing Company 2222 Camden Court Oak Brook IL 60523 800 726 0553 ...

Page 24: ...id Valve 2IN 1OUT x 1000003895 Exit Solenoid Vavle hot x 1000003896 Flow Control 6mm x 1000003897 Flow CONTROL 8mm x 1000003898 Transformer 110 24 x x 1000002636 Lock with 2 Keys x 1000003900 UV OUT Pipe x 1000003902 Blusoda DripTray and Grill complet Set x 1000003903 Wave DripTray and Grill complet Set x 1000003904 BOILER TERMODISK 87 x 1000003905 BOILER SAFETY TERMODISK 110 x 1000003906 BOILER E...

Page 25: ...25 1000003740 Rev A 02 2017 ...

Page 26: ......

Page 27: ......

Page 28: ...160219 ...

Reviews: