12
DSWH160UVPC
Installation and Maintenance Manual
2. Cut, size and connect water and CO
2
piping to fit your installation.
NOTICE:
The water pressure entering the machine must be between 14.5 psi (0.10 MPa) minimum and
51 psi (0.35 MPa) maximum. If the inlet water pressure is higher than 51 psi, the water pressure regulator
supplied must be used.
NOTICE:
An incoming flow rate of >1.0 gallon/minute is recommended for optimal quality of sparkling
water.
NOTICE:
Check all input piping and connections for leaks before connecting to the machine.
Water source:
threaded
fitting
Water
source:
open 3/8"
pipe
Water filter
3/8"
–
quick
connect
adapter
3/8"
–
quick
connect
adapter
Water
pressure
regulator
Water
piping cut
to size
3/8”
water
tubing cut
to size
Water piping
cut to size
To water
cooler
Short
3/8"–
3/8" pipe
Using the quick connect fittings
To connect:
1. Make clean, 90° cut to
piping end.
2. Push piping straight into
fitting until it stops.
3. Pull back to check that
connection is secture.
To disconnect:
1. Press in the end tab.
2. Pull piping out.
3. Release tab.
1/4” Gas tubing
cut to size
Regulator
CO
2
source
3/8” 90° quick
connect elbow -
Needed when unit
is on a countertop
3/8” x 1/4”
quick connect
connector
1/4” tubing
4” long
Recommended total
lenght 6 feet
Use one of two
connection
methods