T 3000 - T 3500
40
9 Barrier
maintenance
WARNING!
Rotating and/or linear movable components can cause serious injuries.
Do not reach into moving parts or handle any moving components during
operation.
Turn the appliance off before any maintenance work, repair work or other
work and secure it against unintentional restarting.
Maintenance T 3000-3500
The maintenance intervals must be decided individually as they are dependent
on the application and the frequency of use. We recommend maintenance at
least once every six months.
1. Check the balancing springs. In case of a faulty spring, all springs must be
replaced simultaneously.
2. Check that the boom is perfectly balanced by the springs (see page 25).
3. Check barrier housing and boom for accidents and damage and replace
where necessary.
4. Ensure that the potential earthing cable is still connected to the housing
and to the door.
5. Check that the operating instructions are complete.
6. Check that all safety equipment works properly (induction loops,
photoelectric barriers, power reversal,...).
7. Check that the barrier is still secure on the foundation.
8. Perform a visual inspection and tighten screws where necessary.
9. Grease the guide bars using multi-purpose grease (temperature range -
30°C to +70° C). Remove excess grease.
Summary of Contents for T 3000
Page 12: ...T 3000 T 3500 11 4 Declaration of incorporation Drawing 2...
Page 18: ...T 3000 T 3500 17 7 2 Mounting dimensions Drawing 3...
Page 34: ...T 3000 T 3500 33 8 4 Circuit diagram Drawing 21...
Page 35: ...T 3000 T 3500 34 Drawing 22...
Page 36: ...T 3000 T 3500 35 Drawing 23...
Page 37: ...T 3000 T 3500 36 Drawing 24...
Page 38: ...T 3000 T 3500 37 Drawing 25...
Page 39: ...T 3000 T 3500 38 Drawing 26...
Page 40: ...T 3000 T 3500 39 Drawing 27...
Page 42: ...T 3000 T 3500 41 10 Layout exploded drawing Drawing 28...