Once the first Wireless Receiver has been installed and operational additional receivers can be installed for redundancy or im-

proved coverage and range.  Each addtional Wireless Receiver must be assigned its own data bus address and must be enrolled 

into the control.  The data bus address setting of any additional Wireless Receivers can be any unused data bus address from 2 to 

10.  ADDRESS 11, 12, 13, 14, 15, or 16 CANNOT BE USED.  

NOTE: Wireless Receiver expanders MUST NEVER be assigned to addresses currently occupied by Hardwired Expand-

ers, and vice versa.  In the example below the first Wireless Receiver (in center) is assigned as Address 2.  The additional 

Receivers are Addresses 3 and 4.   In theory it is possible to install up to 9 total Wireless Receivers on a single M1 Control 

provided none of those addresses are being used by a Hardwired Expander. 

*  For large installations or added coverage in areas experiencing poor wireless conditions additional Wireless Receivers can be connected to the data bus.  Each Receiver 

must be assigned its own Bus Address and be enrolled for proper supervision.  Loss of any enrolled bus device causes a Missing Bus Device Trouble.  

Offices

Shipping

First Wireless 

Receiver

Bus Address 2

Warehouse

Production

Sales

Example of larger Commercial Building with 3 Wireless Receivers

Additional Wireless 

Receiver

Bus Address 3

Additional Wireless 

Receiver

Bus Address 4

Appendix C - Installing Multiple Redundant Receivers

Summary of Contents for ELK-M1XRF319

Page 1: ...found inside INSTALLATION MANUAL L682 Rev B 8 11 20 IMPORTANT NOTE Please consult the Elk M1 Dealer website for downloads of the latest M1 Control firmware and ElkRP Software For compatibility with t...

Page 2: ...using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is induced or eliminated Move the receiver away from the security control Move the an...

Page 3: ...is compatible with that same frequency and protocol A mixture of receivers and transmitters on the same installation is possible as long as each transmitter is installed within range of the receiver w...

Page 4: ...must be set as Address 2 so the first wireless transmitter can be zone 017 This is because M1 only allows wireless zones to reside from Zone 017 to 160 When using ElkRP Programming Software all zones...

Page 5: ...er Valid Pin 01 Bus Module Enrollment Examples of Data Bus Address Settings Conflicts can exist if a group of hardwired zones are allowed to overlap or intrude where wireless sensors zones exist Wirel...

Page 6: ...seful to the receiver in providing a relative signal strength as a reference of the acceptable reliability of the sensor and it s mounting orientation and or location When the Receiver hears a wireles...

Page 7: ...tery is good Following an alarm the zone will remain violated Police Trouble until transmitter sends hourly check in OR until User manually resets zone by pressing and holding the button a second time...

Page 8: ...not send restores Control automatically assumes restoral 8 seconds after violation Enroll Process Remove back cover to activate tamper switch Options Set Opt1 Opt2 to 0 no Loop Set as 2 PIR Motion De...

Page 9: ...rminals DO NOT USE BOTH REED AND EXT SWITCH AT SAME TIME PIR Motion Detector Part 60 703 95 or equivalent Notes Transmitter does not send restores Control automatically assumes restoral 8 seconds afte...

Page 10: ...r selections R02 and R03 for supervision time values Valid values are 0 1 or 3 Factory default setting is 1 Normal Supervision Option for certain types of Transmitters See list of compatible Transmitt...

Page 11: ...event Key 2 Evt 0000 r name of event Key 3 Evt 0000 r name of event Key 4 Evt 0000 r name of event Key 5 Evt 0000 r name of event Key 6 Evt 0000r name of event Key 7 Evt 0000 r name of event Key 8 Evt...

Page 12: ...or RRF H or RRF H or RRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless...

Page 13: ...Addr 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 1...

Page 14: ...97 112 Zones 113 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 1...

Page 15: ...in center is assigned as Address 2 The additional Receivers are Addresses 3 and 4 In theory it is possible to install up to 9 total Wireless Receivers on a single M1 Control provided none of those ad...

Page 16: ...Page 16 ELK M1XRF319 Installation Manual PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Reviews: