ELK-M1XRF319  Installation Manual 

Page 7

ELK

319DWM

  

Door/Window

 

Mini

 

Transmitter

   

>

 

Notes:

 

None

   

>

 

Enroll

 

Process:

 

Remove

 

cover

 

and

 

pull

 

out

 

battery

 

isolation

 

tabs

 

to

 

apply

 

power.

  

Press

 

and

 

release

 

Tamper

 

plunger

 

to

 

send

 

enrollment

 

to

 

panel.

  

 

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

  

>

 

Loop

:

 

Set

 

Loop

 

to

 

2

ELK

319DR

  

Recessed

 

Door

 

Transmitter

   

>

 

Notes:

 

To

 

change

 

battery

 

remove

 

end

 

cap

 

by

 

twisting

 

open

 

1/8"

 

CCW

 

using

 

a

 

coin

 

or

 

screwdriver.

  

Gently

 

grasp

 

edge

 

of

 

board

 

using

 

needle

 

nose

 

pliers

 

and

 

pull

 

out.

  

>

 

Enroll

 

Process:

 

Remove

 

cover

 

and

 

pull

 

out

 

battery

 

isolation

 

tab

 

to

 

apply

 

power.

  

Place

 

magnet

 

to

 

sensor

 

and

 

remove

 

to

 

send

 

enrollment

 

to

 

panel.

  

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

 

 

>

 

Loop

:

 

Set

 

Loop

 

to

 

2

  

ELK

319WS

  

Window

 

Reed

 

&

 

Shock

 

Combo

  

>

 

Notes:

 

The

 

reed

 

and

 

shock

 

each

 

require

 

separate

 

(2)

 

panel

 

zones.

  

The

 

printed

 

TXID

 

#

 

is

 

the

 

shock.

  

The

 

reed

 

is

 

the

 

same

 

TXID

 

#

 

with

 

the

 

last

 

digit

 

increased

 

by

 

+1.

  

The

 

enrollment

 

procedure

 

and

 

order

 

determines

 

which

 

zone

 

is

 

1

st

.

  

>

 

Enroll

 

Process:

  

To

 

enroll

 

both

 

sensors

 

with

 

the

 

shock

 

being

 

the

 

1

st

 

zone

 

use

 

the

 

instructions

 

packed

 

with

 

the

 

sensor.

  

To

 

enroll

 

both

 

sensors

 

with

 

the

 

reed

 

being

 

the

 

1

st

 

zone

 

use

 

these

 

steps:

  

1.

 

Remove

 

cover

 

from

 

sensor.

  

2.

 

Start

 

panel

 

enroll

 

process.

  

3.

 

Hold

 

one

 

finger

 

on

 

the

 

tamper

 

plunger

 

and

 

then

 

remove

 

the

 

battery

 

isolation

 

tabs

 

to

 

apply

 

power.

  

Keep

 

finger

 

on

 

tamper!

  

Panel

 

should

 

enroll

 

the

 

reed

 

and

 

display

 

the

 

printed

 

TXID

 

#

 

+1

 

digit

 

higher.

  

3.

 

Ensure

 

panel

 

enroll

 

is

 

advanced

 

to

 

next

 

zone.

  

4.

 

Release

 

the

 

tamper

 

plunger.

  

Panel

 

should

 

enroll

 

the

 

shock

 

as

 

the

 

2

nd

 

zone

 

and

 

display

 

the

 

actual

 

printed

 

TXID

 

#.

  

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

  

>

 

Loop:

 

Set

 

Loop

 

to

 

2

 

for

 

both

 

1

st

 

and

 

2

nd

 

zone.

ELK

319DG

  

All

 

Weather

 

Door

 

&

 

Gate

 

Transmitter

   

>

 

Notes:

 

Two

 

screw

 

terminals

 

permit

 

an

 

external

 

N/O

 

(normally

 

open)

 

switch

 

to

 

be

 

used

 

instead

 

of

 

the

 

built

in

 

reed.

  

>

 

Enroll

 

Process:

 

Remove

 

cover

 

and

 

pull

 

out

 

battery

 

isolation

 

tabs

 

to

 

apply

 

power.

  

Press

 

and

 

release

 

Tamper

 

plunger

 

to

 

send

 

enrollment

 

to

 

panel.

   

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

 

if

 

using

 

built

in

 

reed

  

OR

  

Set

 

Opt1

 

&

 

Opt2

 

to

 

1

 

(yes)

 

if

 

a

 

external

 

N/O

 

switch

 

is

 

connected

 

to

 

the

 

screw

 

terminals.

  

>

 

Loop:

 

Set

 

Loop

 

to

 

2

 

if

 

using

 

built

in

 

reed

 

OR

  

Set

 

Loop

 

to

 

1

 

if

 

using

 

screw

 

terminals.

  

REED

 

AND

 

EXTERNAL

 

SWITCH

 

ARE

 

NOT

 

DESIGNED

 

TO

 

BE

 

USED

 

AT

 

THE

 

SAME

 

TIME.

ELK

319KF1

  

Single

 

(1)

 

Button

 

Panic

   

>

 

Notes:

 

Programmed

 

differently

 

from

 

a

 

Keyfob.

  

EG:

 

Program

 

M1

 

zone

 

definition

 

as

 

the

 

desired

 

alarm

 

type.

  

Def:

 

23

 

=

 

audible

 

Police.

  

 

>

 

Enroll

 

Process:

 

Press

 

and

 

hold

 

the

 

button.

   

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

   

>

 

Loop

:

 

Set

 

Loop

 

to

 

1

   

Additional

 

info:

 

LED

 

flashes

 

periodically

 

to

 

let

 

User

 

know

 

the

 

battery

 

is

 

good.

  

Following

 

an

 

alarm

 

the

 

zone

 

will

 

remain

 

violated

 

(Police

 

Trouble)

 

until

 

transmitter

 

sends

 

hourly

 

check

in

 

OR

 

until

 

User

 

manually

 

resets

 

zone

 

by

 

pressing

 

and

 

holding

 

the

 

button

 

a

 

second

 

time

 

for

 

~

 

6

 

sec.

 

ELK

319PB1

 

Heavy

 

Duty

 

1

 

Button

 

Panic

   

>

 

Notes:

 

Programmed

 

differently

 

from

 

a

 

Keyfob.

  

EG:

 

Program

 

M1

 

zone

 

definition

 

as

 

the

 

desired

 

alarm

 

type.

  

Def:

 

23

 

=

 

audible

 

Police.

 

 

>

 

Enroll

 

Process:

 

Press

 

and

 

hold

 

the

 

button.

   

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

   

>

 

Loop

:

 

Set

 

Loop

 

to

 

1

   

Additional

 

info:

 

LED

 

flashes

 

periodically

 

to

 

let

 

User

 

know

 

the

 

battery

 

is

 

good.

  

Following

 

an

 

alarm

 

the

 

zone

 

will

 

remain

 

violated

 

(Police

 

Trouble)

 

until

 

transmitter

 

sends

 

hourly

 

check

in

 

OR

 

until

 

User

 

manually

 

resets

 

zone

 

by

 

pressing

 

and

 

holding

 

the

 

button

 

a

 

second

 

time

 

for

 

~

 

6

 

sec.

 

ELK

319KF4

 

Four

 

(4)

 

Button

 

Keyfob

   

>

 

Notes:

 

Program

 

M1

 

zone

 

definition

 

as

 

Keyfob

 

and

 

assign

 

button

 

activations

 

via

 

M1

 

Menu

 

14,

 

submenu

 

4.

  

Icons:

 

Button

 

1=Lock,

 

Button

 

2

 

=Unlock,

 

Button

 

3=Light,

 

Button

 

4=Asterisk.

   

>

 

Enroll

 

Process:

 

Press

 

and

 

hold

 

buttons

 

1

 

&

 

2

 

(Lock

 

&

 

Unlock)

 

at

 

the

 

same

 

time.

  

>

 

Options:

 

Setting

 

Opt1

 

to

 

1

 

(yes)

 

will

 

swap

 

the

 

4

 

button

 

assignments

 

from

 

1

 

thru

 

4

 

to

 

5

 

thru

 

8.

   

Opt2

 

should

 

be

 

left

 

as

 

0

 

(no).

  

>

 

Loop

:

 

N/A

    

Additional

 

info:

 

Combo

 

pressing

 

the

 

Lock

 

and

 

Unlock

 

buttons

 

at

 

same

 

time

 

will

 

trigger

 

the

 

event

 

assigned

 

to

 

Key

 

7.

 

Pressing

 

the

 

Light

 

and

 

Asterisk

 

together

 

will

 

trigger

 

the

 

event

 

assigned

 

to

 

Key

 

8.

ELK

319HRR

 

Heat

 

Rate

 

of

 

Rise

 

Detector

  

>

 

Notes:

 

To

 

activate

 

a

 

manual

 

test

 

hold

 

a

 

magnet

 

next

 

to

 

mark

 

on

 

front

 

edge

 

for

 

~15

 

seconds.

   

>

 

Enroll

 

Process:

 

Pull

 

out

 

battery

 

isolation

 

tabs

 

to

 

apply

 

power

 

and

 

send

 

enrollment

 

to

 

panel.

  

If

 

the

 

unit

 

is

 

already

 

powered

 

try

 

pushing

 

and

 

releasing

 

the

 

tamper.

  

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

  

>

 

Loop

:

 

Set

 

Loop

 

to

 

1

Part Number, Description, Notes, Enroll Process, Options and Loop ID 

Image

When

 

used

 

with

 

Elk

 

M1

 

Controls

 

these

 

transmitters

 

may

 

be

 

enrolled

 

either

 

from

 

Keypad

 

Installer

 

Programming

 

(Menu

 

14.

 

Sub

Menu

 

3)

 

using

 

the

 

“Lrn”

 

method,

 

OR

 

by

 

entering

 

the

 

TXID

 

through

 

Elk’s

 

RP

 

Programming

 

Software.

  

Carefully

 

follow

 

the

 

specific

 

transmitter

 

notes

 

outlined

 

below.

  

IMPORTANT:

 

When

 

using

 

these

 

with

 

other

 

319.5MHz

 

panels

 

it

 

may

 

be

 

necessary

 

to

 

follow

 

enrollment

 

procedures

 

of

 

that

 

panel.

ELK

319PIRC

 

Ceiling

 

Mount

 

360

 

PIR

 

Sensor

  

>

 

Notes:

 

To

 

conserve

 

battery

 

life

 

sensor

 

has

 

a

 

3

minute

 

sleep

 

mode

 

lockout

 

between

 

motion

 

detections

 

and

 

transmissions.

  

For

 

walk

 

testing

 

the

 

3

minute

 

lockout

 

may

 

be

 

avoided

 

by

 

momentarily

 

removing

 

sensor

 

from

 

its

 

base.

  

Walk

 

test

 

times

 

out

 

and

 

ends

 

after

 

1

 

minute

 

of

 

no

 

motion.

  

>

 

Enroll

 

Process:

 

Pull

 

out

 

battery

 

isolation

 

tabs

 

to

 

apply

 

power

 

and

 

send

 

enrollment

 

to

 

panel.

  

If

 

the

 

unit

 

is

 

already

 

powered

 

try

 

pushing

 

and

 

releasing

 

the

 

tamper.

  

>

 

Options:

 

Set

 

Opt1

 

&

 

Opt2

 

to

 

0

 

(no)

  

>

 

Loop

:

 

Set

 

Loop

 

to

 

1

Elk Products 319.5MHz Transmitters 

Summary of Contents for ELK-M1XRF319

Page 1: ...found inside INSTALLATION MANUAL L682 Rev B 8 11 20 IMPORTANT NOTE Please consult the Elk M1 Dealer website for downloads of the latest M1 Control firmware and ElkRP Software For compatibility with t...

Page 2: ...using an indoor antenna have a quality outdoor antenna installed Reorient the receiving antenna until interference is induced or eliminated Move the receiver away from the security control Move the an...

Page 3: ...is compatible with that same frequency and protocol A mixture of receivers and transmitters on the same installation is possible as long as each transmitter is installed within range of the receiver w...

Page 4: ...must be set as Address 2 so the first wireless transmitter can be zone 017 This is because M1 only allows wireless zones to reside from Zone 017 to 160 When using ElkRP Programming Software all zones...

Page 5: ...er Valid Pin 01 Bus Module Enrollment Examples of Data Bus Address Settings Conflicts can exist if a group of hardwired zones are allowed to overlap or intrude where wireless sensors zones exist Wirel...

Page 6: ...seful to the receiver in providing a relative signal strength as a reference of the acceptable reliability of the sensor and it s mounting orientation and or location When the Receiver hears a wireles...

Page 7: ...tery is good Following an alarm the zone will remain violated Police Trouble until transmitter sends hourly check in OR until User manually resets zone by pressing and holding the button a second time...

Page 8: ...not send restores Control automatically assumes restoral 8 seconds after violation Enroll Process Remove back cover to activate tamper switch Options Set Opt1 Opt2 to 0 no Loop Set as 2 PIR Motion De...

Page 9: ...rminals DO NOT USE BOTH REED AND EXT SWITCH AT SAME TIME PIR Motion Detector Part 60 703 95 or equivalent Notes Transmitter does not send restores Control automatically assumes restoral 8 seconds afte...

Page 10: ...r selections R02 and R03 for supervision time values Valid values are 0 1 or 3 Factory default setting is 1 Normal Supervision Option for certain types of Transmitters See list of compatible Transmitt...

Page 11: ...event Key 2 Evt 0000 r name of event Key 3 Evt 0000 r name of event Key 4 Evt 0000 r name of event Key 5 Evt 0000 r name of event Key 6 Evt 0000r name of event Key 7 Evt 0000 r name of event Key 8 Evt...

Page 12: ...or RRF H or RRF H or RRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Starting Zn ID 49 Data Bus Addr 4 Zn 49 64 M1XRF Cells marked indicate a Reserved Address which can only be used for wireless...

Page 13: ...Addr 11 Zn 161 176 M1XRF Data Bus Addr 2 Zn 17 32 Data Bus Addr 3 Zn 33 48 Data Bus Addr 4 Zn 49 64 Data Bus Addr 5 Zn 65 80 Data Bus Addr 6 Zn 81 96 Data Bus Addr 7 Zn 97 112 Data Bus Addr 8 Zn 113 1...

Page 14: ...97 112 Zones 113 128 Zones 129 144 Zones 145 160 Zones 161 176 Zones 177 192 Zones 193 208 Bus Addr x Bus Addr 2 Bus Addr 3 Bus Addr 4 Bus Addr 5 Bus Addr 6 Bus Addr 7 Bus Addr 8 Bus Addr 9 Bus Addr 1...

Page 15: ...in center is assigned as Address 2 The additional Receivers are Addresses 3 and 4 In theory it is possible to install up to 9 total Wireless Receivers on a single M1 Control provided none of those ad...

Page 16: ...Page 16 ELK M1XRF319 Installation Manual PO Box 100 3266 US Hwy 70 West Hildebran NC 28637 828 397 4200 828 397 4415 Fax http www elkproducts com...

Reviews: