ELK-M1XRF319 Installation Manual
Page 7
ELK
‐
319DWM
Door/Window
Mini
Transmitter
>
Notes:
None
>
Enroll
Process:
Remove
cover
and
pull
out
battery
isolation
tabs
to
apply
power.
Press
and
release
Tamper
plunger
to
send
enrollment
to
panel.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
2
ELK
‐
319DR
Recessed
Door
Transmitter
>
Notes:
To
change
battery
remove
end
cap
by
twisting
open
1/8"
CCW
using
a
coin
or
screwdriver.
Gently
grasp
edge
of
board
using
needle
nose
pliers
and
pull
out.
>
Enroll
Process:
Remove
cover
and
pull
out
battery
isolation
tab
to
apply
power.
Place
magnet
to
sensor
and
remove
to
send
enrollment
to
panel.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
2
ELK
‐
319WS
Window
Reed
&
Shock
Combo
>
Notes:
The
reed
and
shock
each
require
separate
(2)
panel
zones.
The
printed
TXID
#
is
the
shock.
The
reed
is
the
same
TXID
#
with
the
last
digit
increased
by
+1.
The
enrollment
procedure
and
order
determines
which
zone
is
1
st
.
>
Enroll
Process:
To
enroll
both
sensors
with
the
shock
being
the
1
st
zone
use
the
instructions
packed
with
the
sensor.
To
enroll
both
sensors
with
the
reed
being
the
1
st
zone
use
these
steps:
1.
Remove
cover
from
sensor.
2.
Start
panel
enroll
process.
3.
Hold
one
finger
on
the
tamper
plunger
and
then
remove
the
battery
isolation
tabs
to
apply
power.
Keep
finger
on
tamper!
Panel
should
enroll
the
reed
and
display
the
printed
TXID
#
+1
digit
higher.
3.
Ensure
panel
enroll
is
advanced
to
next
zone.
4.
Release
the
tamper
plunger.
Panel
should
enroll
the
shock
as
the
2
nd
zone
and
display
the
actual
printed
TXID
#.
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop:
Set
Loop
to
2
for
both
1
st
and
2
nd
zone.
ELK
‐
319DG
All
Weather
Door
&
Gate
Transmitter
>
Notes:
Two
screw
terminals
permit
an
external
N/O
(normally
open)
switch
to
be
used
instead
of
the
built
‐
in
reed.
>
Enroll
Process:
Remove
cover
and
pull
out
battery
isolation
tabs
to
apply
power.
Press
and
release
Tamper
plunger
to
send
enrollment
to
panel.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
if
using
built
‐
in
reed
OR
Set
Opt1
&
Opt2
to
1
(yes)
if
a
external
N/O
switch
is
connected
to
the
screw
terminals.
>
Loop:
Set
Loop
to
2
if
using
built
‐
in
reed
OR
Set
Loop
to
1
if
using
screw
terminals.
REED
AND
EXTERNAL
SWITCH
ARE
NOT
DESIGNED
TO
BE
USED
AT
THE
SAME
TIME.
ELK
‐
319KF1
Single
(1)
Button
Panic
>
Notes:
Programmed
differently
from
a
Keyfob.
EG:
Program
M1
zone
definition
as
the
desired
alarm
type.
Def:
23
=
audible
Police.
>
Enroll
Process:
Press
and
hold
the
button.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
1
Additional
info:
LED
flashes
periodically
to
let
User
know
the
battery
is
good.
Following
an
alarm
the
zone
will
remain
violated
(Police
Trouble)
until
transmitter
sends
hourly
check
‐
in
OR
until
User
manually
resets
zone
by
pressing
and
holding
the
button
a
second
time
for
~
6
sec.
ELK
‐
319PB1
Heavy
Duty
1
Button
Panic
>
Notes:
Programmed
differently
from
a
Keyfob.
EG:
Program
M1
zone
definition
as
the
desired
alarm
type.
Def:
23
=
audible
Police.
>
Enroll
Process:
Press
and
hold
the
button.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
1
Additional
info:
LED
flashes
periodically
to
let
User
know
the
battery
is
good.
Following
an
alarm
the
zone
will
remain
violated
(Police
Trouble)
until
transmitter
sends
hourly
check
‐
in
OR
until
User
manually
resets
zone
by
pressing
and
holding
the
button
a
second
time
for
~
6
sec.
ELK
‐
319KF4
Four
(4)
Button
Keyfob
>
Notes:
Program
M1
zone
definition
as
Keyfob
and
assign
button
activations
via
M1
Menu
14,
submenu
4.
Icons:
Button
1=Lock,
Button
2
=Unlock,
Button
3=Light,
Button
4=Asterisk.
>
Enroll
Process:
Press
and
hold
buttons
1
&
2
(Lock
&
Unlock)
at
the
same
time.
>
Options:
Setting
Opt1
to
1
(yes)
will
swap
the
4
button
assignments
from
1
thru
4
to
5
thru
8.
Opt2
should
be
left
as
0
(no).
>
Loop
:
N/A
Additional
info:
Combo
pressing
the
Lock
and
Unlock
buttons
at
same
time
will
trigger
the
event
assigned
to
Key
7.
Pressing
the
Light
and
Asterisk
together
will
trigger
the
event
assigned
to
Key
8.
ELK
‐
319HRR
Heat
Rate
of
Rise
Detector
>
Notes:
To
activate
a
manual
test
hold
a
magnet
next
to
mark
on
front
edge
for
~15
seconds.
>
Enroll
Process:
Pull
out
battery
isolation
tabs
to
apply
power
and
send
enrollment
to
panel.
If
the
unit
is
already
powered
try
pushing
and
releasing
the
tamper.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
1
Part Number, Description, Notes, Enroll Process, Options and Loop ID
Image
When
used
with
Elk
M1
Controls
these
transmitters
may
be
enrolled
either
from
Keypad
Installer
Programming
(Menu
14.
Sub
‐
Menu
3)
using
the
“Lrn”
method,
OR
by
entering
the
TXID
through
Elk’s
RP
Programming
Software.
Carefully
follow
the
specific
transmitter
notes
outlined
below.
IMPORTANT:
When
using
these
with
other
319.5MHz
panels
it
may
be
necessary
to
follow
enrollment
procedures
of
that
panel.
ELK
‐
319PIRC
Ceiling
Mount
360
PIR
Sensor
>
Notes:
To
conserve
battery
life
sensor
has
a
3
‐
minute
sleep
mode
lockout
between
motion
detections
and
transmissions.
For
walk
testing
the
3
‐
minute
lockout
may
be
avoided
by
momentarily
removing
sensor
from
its
base.
Walk
test
times
out
and
ends
after
1
minute
of
no
motion.
>
Enroll
Process:
Pull
out
battery
isolation
tabs
to
apply
power
and
send
enrollment
to
panel.
If
the
unit
is
already
powered
try
pushing
and
releasing
the
tamper.
>
Options:
Set
Opt1
&
Opt2
to
0
(no)
>
Loop
:
Set
Loop
to
1
Elk Products 319.5MHz Transmitters